Helix-fixed leadless pacemaker implantation through a valve-in-valve tricuspid prosthesis via the femoral approach.
J Interv Card Electrophysiol
; 67(5): 915-917, 2024 Aug.
Article
em En
| MEDLINE
| ID: mdl-38684636
ABSTRACT
Leadless pacemakers offer the opportunity to avoid transvenous hardware among patients with tricuspid valve prostheses. We present the first case of a helix-based fixation leadless pacemaker implanted through valve-in-valve tricuspid prostheses in a 43-year-old female with extensive prior cardiac history. At the time of presentation, epicardial pacing was no longer a viable option in the setting of pacemaker dependence. Placement of a helix-fixed, leadless right ventricular pacemaker was performed as a bridge to dual-chamber leadless pacing. This was safely and effectively performed and highlighted favorable procedural characteristics that included RV cavity dimensions and prosthesis type.