A systematic review of factors impacting intraoral scanning accuracy in implant dentistry with emphasis on scan bodies.
Gehrke, Peter; Rashidpour, Mahsa; Sader, Robert; Weigl, Paul.
Afiliação
  • Gehrke P; Department of Postgraduate Education, Master of Oral Implantology, Center for Dentistry and Oral Medicine (Carolinum), Johann Wolfgang Goethe University, Theodor-Stern-Kai 7, 60596, Frankfurt, Germany. dr-gehrke@prof-dhom.de.
  • Rashidpour M; Private Practice for Oral Surgery and Implant Dentistry, Bismarckstraße 27, 67059, Ludwigshafen, Germany. dr-gehrke@prof-dhom.de.
  • Sader R; Master of Oral Implantology, Center for Dentistry and Oral Medicine, Johann Wolfgang Goethe University, Frankfurt, Germany.
  • Weigl P; Private Practice for Implant dentistry and Prosthodontics, Tehran, Iran.
Int J Implant Dent ; 10(1): 20, 2024 May 01.
Article em En | MEDLINE | ID: mdl-38691258
ABSTRACT

PURPOSE:

The purpose of this systematic review was to explore and identify the factors that influence the accuracy of intraoral scanning in implant dentistry, with a specific focus on scan bodies (ISBs).

METHODS:

Following the PRISMA 2020 guidelines, this study conducted a thorough electronic search across MedLine, PubMed, and Scopus to identify relevant studies. Articles were screened based on titles, abstracts, and full texts for relevance. The Robins I tool assessed the risk of bias in various study types. Data extraction occurred based on predetermined parameters for studying specimens and assessing outcomes.

RESULTS:

16 studies met the specified criteria and were consequently included in the systematic review. Due to variations in variables and methods across the selected studies, statistical comparison of results was not feasible. Therefore, a descriptive review approach was chosen, acknowledging the substantial heterogeneity in the reviewed literature.

CONCLUSIONS:

The precision of virtual scan results is contingent upon diverse characteristics of ISBs and implants. These factors encompass their placement within the dental arch, structural design, shape, material composition, color, and the manufacturing system, all of which contribute to scan accuracy. Additionally, considerations such as the intraoral scanner (IOS) type, scanning technique, use of scan aids, inter-implant distance, scan span, and the number of implants warrant evaluation. In the context of capturing implant positions, intraoral scanning with ISBs demonstrates comparable accuracy to traditional impression methods, particularly in single and short-span scenarios. However, the existing data lacks sufficient information on in vivo applications to formulate clinical recommendations.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários Limite: Humans Idioma: En Revista: Int J Implant Dent Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários Limite: Humans Idioma: En Revista: Int J Implant Dent Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha