Air dispersal of multi-drug-resistant organisms including meticillin-resistant Staphylococcus aureus, carbapenem-resistant Acinetobacter baumannii and carbapenemase-producing Enterobacterales in general wards: surveillance culture of air grilles.
J Hosp Infect
; 149: 26-35, 2024 Jul.
Article
em En
| MEDLINE
| ID: mdl-38705476
ABSTRACT
BACKGROUND:
The environmental surveillance of air grilles in clinical areas has not been systematically analysed.METHODS:
Samples were collected from frequently touched items (N = 529), air supply (N = 295) and exhaust (N = 184) grilles in six medical and 11 surgical wards for the cultures of multi-drug-resistant organisms (MDROs) meticillin-resistant Staphylococcus aureus (MRSA), carbapenem-resistant Acinetobacter baumannii (CRAB) and carbapenemase-producing Enterobacterales (CPE), and isolates were selected for whole-genome sequencing (WGS). The contamination rates were correlated with the colonization pressures of the respective MDROs.RESULTS:
From 3rd October to 21st November 2023, 9.8% (99/1008) of the samples tested positive, with MRSA (24.2%, 24/99), CRAB (59.6%, 59/99) and CPE (2.0%, 2/99), being the only detected MDROs. The contamination rate in air exhaust grilles (26.6%, 49/184) was significantly higher than in air supply grilles (5.8%, 17/295; P<0.001). The contamination rate of air exhaust grilles with any MDRO in acute medical wards (73.7%, 14/19) was significantly higher than in surgical wards (12.5%, 4/32; P<0.001). However, there was no difference in the contamination rate of air exhaust grilles between those located inside and outside the cohort cubicles for MDROs (27.1%, 13/48 vs 28.8%, 30/104; P=0.823). Nevertheless, the weekly CRAB colonization pressure showed a significant correlation with the overall environmental contamination rate (r = 0.878; 95% confidence interval (CI) 0.136-0.986; P=0.004), as well as with the contamination rate in air supply grilles (r = 0.960; 95% CI 0.375-0.999; P<0.001) and air exhaust grilles (r = 0.850; 95% CI 0.401-0.980; P=0.008). WGS demonstrated clonal relatedness of isolates collected from patients and air exhaust grilles.CONCLUSIONS:
Air grilles may serve as MDRO reservoirs. Cohort nursing in open cubicles may not completely prevent MDRO transmission through air dispersal, prompting the consideration of future hospital design.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Farmacorresistência Bacteriana Múltipla
/
Acinetobacter baumannii
/
Microbiologia do Ar
/
Staphylococcus aureus Resistente à Meticilina
Limite:
Humans
Idioma:
En
Revista:
J Hosp Infect
Ano de publicação:
2024
Tipo de documento:
Article
País de afiliação:
China