Your browser doesn't support javascript.
loading
MAN-C: A masked autoencoder neural cryptography based encryption scheme for CT scan images.
Kumar, Kishore; Tanwar, Sarvesh; Kumar, Shishir.
Afiliação
  • Kumar K; Amity Institute of Information Technology, Amity University, Noida, Uttar Pradesh, India.
  • Tanwar S; Amity Institute of Information Technology, Amity University, Noida, Uttar Pradesh, India.
  • Kumar S; School of Information Science and Technology, Babasaheb Bhimrao Ambedkar University, Lucknow, Uttar Pradesh, India.
MethodsX ; 12: 102738, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38715952
ABSTRACT
Sharing medical images securely is very important towards keeping patients' data confidential. In this paper we propose MAN-C a Masked Autoencoder Neural Cryptography based encryption scheme for sharing medical images. The proposed technique builds upon recently proposed masked autoencoders. In the original paper, the masked autoencoders are used as scalable self-supervised learners for computer vision which reconstruct portions of originally patched images. Here, the facility to obfuscate portions of input image and the ability to reconstruct original images is used an encryption-decryption scheme. In the final form, masked autoencoders are combined with neural cryptography consisting of a tree parity machine and Shamir Scheme for secret image sharing. The proposed technique MAN-C helps to recover the loss in image due to noise during secret sharing of image.•Uses recently proposed masked autoencoders, originally designed as scalable self-supervised learners for computer vision, in an encryption-decryption setup.•Combines autoencoders with neural cryptography - the advantage our proposed approach offers over existing technique is that (i) Neural cryptography is a new type of public key cryptography that is not based on number theory, requires less computing time and memory and is non-deterministic in nature, (ii) masked auto-encoders provide additional level of obfuscation through their deep learning architecture.•The proposed scheme was evaluated on dataset consisting of CT scans made public by The Cancer Imaging Archive (TCIA). The proposed method produces better RMSE values between the input the encrypted image and comparable correlation values between the input and the output image with respect to the existing techniques.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: MethodsX Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: MethodsX Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia
...