The burden of radiation exposure in congenital heart disease: the Italian cohort profile and bioresource collection in HARMONIC project.
Ital J Pediatr
; 50(1): 100, 2024 May 17.
Article
em En
| MEDLINE
| ID: mdl-38760836
ABSTRACT
BACKGROUND:
The European-funded Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics (HARMONIC) project aims to improve knowledge on the effects of medical exposure to ionizing radiation (IR) received during childhood. One of its objectives is to build a consolidated European cohort of pediatric patients who have undergone cardiac catheterization (Cath) procedures, with the goal of enhancing the assessment of long-term radiation-associated cancer risk. The purpose of our study is to provide a detailed description of the Italian cohort contributing to the HARMONIC project, including an analysis of cumulative IR exposure, reduction trend over the years and an overview of the prospective collection of biological samples for research in this vulnerable population.METHODS:
In a single-center retrospective cohort study, a total of 584 patients (323 males) with a median age of 6 (2-13) years, referred at the Pediatric Cardiology in Niguarda Hospital from January 2015 to October 2023, were included. Biological specimens from a subset of 60 patients were prospectively collected for biobanking at baseline, immediately post-procedure and after 12 months.RESULTS:
Two hundred fifty-nine (44%) patients were under 1 year old at their first procedure. The median KAP/weight was 0.09 Gy·cm2/kg (IQR 0.03-0.20), and the median fluoroscopy time was 8.10 min (IQR 4.00-16.25). KAP/weight ratio showed a positive correlation with the fluoroscopy time (Spearman's rho = 0.679, p < 0.001). Significant dose reduction was observed either after implementation of an upgraded technology system and a radiation training among staff. The Italian cohort includes 1858 different types of specimens for Harmonic biobank, including blood, plasma, serum, clot, cell pellet/lymphocytes, saliva.CONCLUSIONS:
In the Italian Harmonic cohort, radiation dose in cardiac catheterization varies by age and procedure type. An institution's radiological protection strategy has contributed to a reduction in radiation dose over time. Biological samples provide a valuable resource for future research, offering an opportunity to identify potential early biomarkers for health surveillance and personalized risk assessment.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Cateterismo Cardíaco
/
Exposição à Radiação
/
Cardiopatias Congênitas
Limite:
Adolescent
/
Child
/
Child, preschool
/
Female
/
Humans
/
Male
País/Região como assunto:
Europa
Idioma:
En
Revista:
Ital J Pediatr
Assunto da revista:
PEDIATRIA
Ano de publicação:
2024
Tipo de documento:
Article
País de afiliação:
Itália
País de publicação:
Reino Unido