Your browser doesn't support javascript.
loading
Diagnostic values of questionnaires of Convergence Insufficiency Symptom Survey and College of Optometrists Vision Development Quality of Life in the screening of convergence insufficiency.
Xiong, Ling; Chen, Qian; Wu, Ye.
Afiliação
  • Xiong L; Department of Ophthalmology, West China Hospital, Sichuan University/Laboratory of Optometry and Vision Science, West China School of Medicine, Chengdu 610041, Sichuan Province, China.
  • Chen Q; Department of Clinical Research Management, Center of Biostatistics, Design, Measurement and Evaluation, West China Hospital, Sichuan University, Chengdu 610041, Sichuan Province, China.
  • Wu Y; Department of Ophthalmology, West China Hospital, Sichuan University/Laboratory of Optometry and Vision Science, West China School of Medicine, Chengdu 610041, Sichuan Province, China.
Int J Ophthalmol ; 17(5): 904-908, 2024.
Article em En | MEDLINE | ID: mdl-38766349
ABSTRACT

AIM:

To compare and analyse the diagnostic efficacy of the College of Optometrists Vision Development Quality of Life Questionnaire (COVD-QOL) and the Convergence Insufficiency Symptom Survey (CISS) in detecting convergence insufficiency and to compare their diagnostic value in clinical applications.

METHODS:

Using the diagnostic test method, 62 adult patients with convergence insufficiency (age 24.74±3.75y) and 62 normal participants (age 23.61±3.13y) who visited the Optometry Clinic of West China Hospital of Sichuan University from April 2021 to January 2023 were included. All subjects completed the CISS and COVD-QOL. Statistical analysis of the sensitivity and specificity of the CISS and COVD-QOL and comparison and joint experimental analysis of their diagnostic efficacy were performed.

RESULTS:

The sensitivity of the CISS and COVD-QOL for convergence insufficiency was 64.5% and 71.0%, respectively, while the specificity was 96.8% and 67.7%, respectively. Compared to the CISS alone, the combination of the CISS and COVD-QOL demonstrated lower sensitivity and specificity. The areas under the receiver operating characteristic curve of CISS, COVD-QOL and CISS combined with COVD-QOL were 0.806, 0.694 and 0.782, respectively.

CONCLUSION:

Considering the low sensitivity of the CISS and the low specificity of the COVD-QOL, it is recommended to supplement these questionnaires with other screening tests for the detection of convergence insufficiency.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Int J Ophthalmol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China