Your browser doesn't support javascript.
loading
AlphaLISA-Based Immunoassay for Detection of Troponin T in Serum of Patients with Acute Myocardial Infarction.
Lv, Wei; Li, Qian; Tang, Yan; Qin, Yuan; Zhou, Xiumei; Zhao, Xueqin; Zheng, Zhencang; Huang, Biao.
Afiliação
  • Lv W; College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China.
  • Li Q; Zhejiang Provincial People's Hospital, People's Hospital of Hangzhou Medical College, Hangzhou, China.
  • Tang Y; College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China.
  • Qin Y; College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China.
  • Zhou X; College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China.
  • Zhao X; College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China. zhaoxueqin2004@163.com.
  • Zheng Z; Taizhou Central Hospital(Taizhou University Hospital), Taizhou, 318000, China. Zhengzc2023@163.com.
  • Huang B; College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China. jswxhb@163.com.
J Fluoresc ; 2024 May 23.
Article em En | MEDLINE | ID: mdl-38780833
ABSTRACT
Survival and prognosis of patients with acute myocardial infarction (AMI) are highly dependent on rapid and accurate diagnosis of myocardial damage. Troponin T is the primary diagnostic biomarker and is widely used in clinical practice. Amplified luminescent proximity homogeneous assay (AlphaLISA) may provide a solution to rapidly detect a small amount of analyte through molecular interactions between special luminescent donor beads and acceptor bead. Here, a double-antibody sandwich assay was introduced into AlphaLISA for rapid detection for early diagnosis of AMI and disease staging evaluation. The performance of the assay was evaluated. The study found that the cTnT assay has a linear range of 48.66 to 20,000 ng/L with a limit of detection of 48.66 ng/L. In addition, the assay showed no cross-reactivity with other classic biomarkers of myocardial infarction and was highly reproducible with intra- and inter-batch coefficients of variation of less than 10%, notably, only 3 min was taken, which is particularly suitable for clinical diagnosis. These results suggest that our method can be conveniently applied in the clinic to determine the severity of the patient's condition.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Fluoresc Assunto da revista: BIOFISICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Fluoresc Assunto da revista: BIOFISICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Holanda