Your browser doesn't support javascript.
loading
Capillary blood self-collection for high-throughput proteomics.
El-Sabawi, Bassim; Huang, Shi; Tanriverdi, Kahraman; Perry, Andrew S; Amancherla, Kaushik; Jackson, Natalie; Hulsey, Jenna; Freedman, Jane E; Shah, Ravi; Lindman, Brian R.
Afiliação
  • El-Sabawi B; Department of Medicine, Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Huang S; Department of Biostatistics, Vanderbilt University School of Medicine, Nashville, Tennessee, USA.
  • Tanriverdi K; Department of Medicine, Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Perry AS; Department of Medicine, Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Amancherla K; Department of Medicine, Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Jackson N; Department of Medicine, Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Hulsey J; Structural Heart and Valve Center, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Freedman JE; Department of Medicine, Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Shah R; Structural Heart and Valve Center, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Lindman BR; Department of Medicine, Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
Proteomics ; 24(16): e2300607, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38783781
ABSTRACT
In this study, we sought to compare protein concentrations obtained from a high-throughput proteomics platform (Olink) on samples collected using capillary blood self-collection (with the Tasso+ device) versus standard venipuncture (control). Blood collection was performed on 20 volunteers, including one sample obtained via venipuncture and two via capillary blood using the Tasso+ device. Tasso+ samples were stored at 2°C-8°C for 24-hs (Tasso-24) or 48-h (Tasso-48) prior to processing to simulate shipping times from a study participant's home. Proteomics were analyzed using Olink (384 Inflammatory Panel). Tasso+ blood collection was successful in 37/40 attempts. Of 230 proteins included in our analysis, Pearson correlations (r) and mean coefficient of variation (CV) between Tasso-24 or Tasso-48 versus venipuncture were variable. In the Tasso-24 analysis, 34 proteins (14.8%) had both a correlation r > 0.5 and CV < 0.20. In the Tasso-48 analysis, 68 proteins (29.6%) had a correlation r > 0.5 and CV < 0.20. Combining the Tasso-24 and Tasso-48 analyses, 26 (11.3%) proteins met these thresholds. We concluded that protein concentrations from Tasso+ samples processed 24-48 h after collection demonstrated wide technical variability and variable correlation with a venipuncture gold-standard. Use of home capillary blood self-collection for large-scale proteomics should be limited to select proteins with good agreement with venipuncture.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coleta de Amostras Sanguíneas / Proteômica Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Proteomics Assunto da revista: BIOQUIMICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coleta de Amostras Sanguíneas / Proteômica Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Proteomics Assunto da revista: BIOQUIMICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Alemanha