Your browser doesn't support javascript.
loading
Finite element analysis of implanted lumbar spine: Effects of open laminectomy plus PLF and open laminectomy plus TLIF surgical approaches on L3-L4 FSU.
Pradeep, Kishore; Pal, Bidyut; Mukherjee, Kaushik; Shetty, Gautam M.
Afiliação
  • Pradeep K; Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology (IIEST), Shibpur, Howrah 711103, West Bengal, India.
  • Pal B; Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology (IIEST), Shibpur, Howrah 711103, West Bengal, India. Electronic address: bidyutpal@mech.iiests.ac.in.
  • Mukherjee K; Department of Mechanical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110 016, India.
  • Shetty GM; QI Spine Clinic, Mumbai, India; Knee & Orthopaedic Clinic, Mumbai, India.
Med Eng Phys ; 128: 104178, 2024 06.
Article em En | MEDLINE | ID: mdl-38789215
ABSTRACT
Several finite element (FE) studies reported performances of various lumbar fusion surgical approaches. However, comparative studies on the performance of Open Laminectomy plus Posterolateral Fusion (OL-PLF) and Open Laminectomy plus Transforaminal Interbody Fusion (OL-TLIF) surgical approaches are rare. In the current FE study, the variation in ranges of motions (ROM), stress-strain distributions in an implanted functional spinal unit (FSU) and caudal adjacent soft structures between OL-PLF and OL-TLIF virtual models were investigated. The implanted lumbar spine FE models were developed from subject-specific computed tomography images of an intact spine and solved for physiological loadings such as compression, flexion, extension and lateral bending. Reductions in the ROMs of L1-L5 (49 % to 59 %) and L3-L4 implanted FSUs (91 % to 96 %) were observed for both models. Under all the loading cases, the maximum von Mises strain observed in the implanted segment of both models exceeds the mean compressive yield strain for the vertebra. The maximum von Mises stress and strain observed on the caudal adjacent soft structures of both the implanted models are at least 22 % higher than the natural spine model. The findings indicate the risk of failure in the implanted FSUs and higher chances of adjacent segment degeneration for both models.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fusão Vertebral / Análise de Elementos Finitos / Laminectomia / Vértebras Lombares Limite: Humans / Male Idioma: En Revista: Med Eng Phys Assunto da revista: BIOFISICA / ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fusão Vertebral / Análise de Elementos Finitos / Laminectomia / Vértebras Lombares Limite: Humans / Male Idioma: En Revista: Med Eng Phys Assunto da revista: BIOFISICA / ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia