Your browser doesn't support javascript.
loading
Optical crosstalk of protective cover on MPPC array for TOF PET detector.
Yoshida, Eiji; Obata, Fujino; Yamaya, Taiga.
Afiliação
  • Yoshida E; National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan.
  • Obata F; National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan.
  • Yamaya T; National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan.
Phys Med Biol ; 69(12)2024 Jun 10.
Article em En | MEDLINE | ID: mdl-38815615
ABSTRACT
Objective. Time-of-flight (TOF) is an important factor that directly affects the image quality of PET systems, and various attempts have been made to improve the coincidence resolving time (CRT) of PET detectors. For independent readout detectors, the timing is acquired for each silicon photomultiplier (SiPM), so they are less sensitive to diffused scintillation light, resulting in a better CRT. Further improvement can be expected if the light can be focused on a single SiPM. However, existing SiPM arrays have a thin protective cover on the SiPM and the gap between the SiPMs is filled with either air or the protective cover, so the light must diffuse through the cover. In this work, we investigated optical crosstalk in the protective cover to improve the CRT.Approach. We used 3.1 × 3.1 × 20 mm3fast LGSO crystals and 3 mm square 8 × 8 multi pixel photon counter (MPPC) arrays. Pitch of the MPPCs was 3.2 mm and thickness of the protective cover on them was 150µm. To reduce diffusion of scintillation light in the protective cover, the part of the inactive areas on the MPPC array were optically separated using reflective material. Specifically, 50, 100, 150, and 350µm deep grid-shaped slits were made along the inactive area of the MPPCs and they were filled with BaSO4powder as the reflective material.Main results. Coincidence counts were measured with a pair of TOF detectors, and the CRT was shorter with a deeper slit depth. The CRT before improvement was 235 ps, and using the cover having the 350µm deep slits filled with reflective material lowered the CRT to 211 ps.Significance. Up to 10% of the scintillation light was diffused to other MPPCs by the protective cover, and the CRT was degraded by 10% due to optical crosstalk of the cover. The proposed method promises to improve the CRT of the TOF detector.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia por Emissão de Pósitrons Idioma: En Revista: Phys Med Biol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia por Emissão de Pósitrons Idioma: En Revista: Phys Med Biol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão País de publicação: Reino Unido