Your browser doesn't support javascript.
loading
Outcomes of a Double-Cup Construct to Treat Paprosky 3A and 3B Acetabular Defects at a Mean of 39 Months.
Liu, Quan; Zhang, Rong-Wei; Ma, Rui-Xiang; Zhu, Wan-Bo; Zhang, Xian-Zuo; Zhu, Chen.
Afiliação
  • Liu Q; Division of Life Sciences and Medicine, Department of Orthopaedics, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei, Anhui, China.
  • Zhang RW; Division of Life Sciences and Medicine, Department of Orthopaedics, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei, Anhui, China.
  • Ma RX; Division of Life Sciences and Medicine, Department of Orthopaedics, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei, Anhui, China.
  • Zhu WB; Department of Orthopedics, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Jiao Tong University, Shanghai, China.
  • Zhang XZ; Division of Life Sciences and Medicine, Department of Orthopaedics, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei, Anhui, China.
  • Zhu C; Division of Life Sciences and Medicine, Department of Orthopaedics, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei, Anhui, China.
J Arthroplasty ; 2024 May 31.
Article em En | MEDLINE | ID: mdl-38823520
ABSTRACT

BACKGROUND:

Modular reconstruction systems based on porous tantalum (PT) prosthetic components have been increasingly used for the treatment of complex acetabular bone defects in revision total hip arthroplasty. We report a novel technique that applies a revision cup as a "super-augment" to form a "double-cup" construct for Paprosky type III defects.

METHODS:

A retrospective review was conducted on revision total hip arthroplasty cases, comparing those treated with double-cup constructs (DC group, n = 48) to those treated with PT shells and augments (PT group, n = 48). All procedures were performed at the same institute between 2017 and 2022. Clinical outcome evaluation utilized the Harris Hip Score, Oxford Hip Score, and the 36-Item Short Form Survey. Preoperative and postoperative radiographic assessments measured hip center of rotation (COR) position and leg length discrepancy. Additionally, postoperative complications and implant survivorship were monitored during the follow-up period.

RESULTS:

The clinical outcomes improved substantially in both groups, which showed no significant difference in the Harris Hip Score (P = .786), the Oxford Hip Score (P = .570), and the 36-Item Short Form Survey (P = .691). Compared to the PT group, the reconstruction COR was significantly closer to the anatomic COR (vertical distance 2.630 versus 7.355 mm, P = .0034; horizontal distance 1.881 versus -6.413 mm, P < .0001) in Paprosky 3B type defects. Additionally, postoperative leg length discrepancy was less in the DC group (-8.252 versus -1.821 mm, P = .0008). Dislocation was the main complication in the DC group, and only 1 patient received re-revision due to repeated dislocation. The cumulative survival rate of the DC group (100%; 95% confidence interval 100) was better than the PT group (83.4%; 95% confidence interval 70.5 to 98.6) when re-revisions for aseptic loosening were the endpoint (P = .046).

CONCLUSIONS:

The DC is a reliable revision technique for the reconstruction of Paprosky type III bone defects. Although dislocation remains challenging, the biomechanically superior restoration achieved by this technique lowers the risk of aseptic loosening.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China
...