Your browser doesn't support javascript.
loading
Novel motion correction algorithm improves diagnostic performance of CT fractional flow reserve.
Yang, Wenli; Yu, Lihua; Yu, Yarong; Dai, Xu; Yang, Wenyi; Zhang, Jiayin.
Afiliação
  • Yang W; Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, #85 Wujin Rd, Shanghai, China.
  • Yu L; Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, #85 Wujin Rd, Shanghai, China.
  • Yu Y; Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, #85 Wujin Rd, Shanghai, China.
  • Dai X; Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, #85 Wujin Rd, Shanghai, China.
  • Yang W; Department of Cardiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, #85 Wujin Rd, Shanghai, China.
  • Zhang J; Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, #85 Wujin Rd, Shanghai, China. Electronic address: andrewssmu@msn.com.
Eur J Radiol ; 176: 111538, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38838412
ABSTRACT

OBJECTIVES:

This study aimed to investigate the diagnostic performance of computed tomography (CT) fractional flow reserve (CT-FFR) derived from standard images (STD) and images processed via first-generation (SnapShot Freeze, SSF1) and second-generation (SnapShot Freeze 2, SSF2) motion correction algorithms.

METHODS:

151 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography (ICA)/FFR within 3 months were retrospectively included. CCTA images were reconstructed using an iterative reconstruction technique and then further processed through SSF1 and SSF2 algorithms. All images were divided into three groups STD, SSF1, and SSF2. Obstructive stenosis was defined as a diameter stenosis of ≥ 50 % in the left main artery or ≥ 70 % in other epicardial vessels. Stenosis with an FFR of ≤ 0.8 or a diameter stenosis of ≥ 90 % (as revealed via ICA) was considered ischemic. In patients with multiple lesions, the lesion with lowest CT-FFR was used for patient-level analysis.

RESULTS:

The overall quality score in SSF2 group (median = 3.67) was markedly higher than that in STD (median = 3) and SSF1 (median = 3) groups (P < 0.001). The best correlation (r = 0.652, P < 0.001) and consistency (mean difference = 0.04) between the CT-FFR and FFR values were observed in the SSF2 group. At the per-lesion level, CT-FFRSSF2 outperformed CT-FFRSSF1 in diagnosing ischemic lesions (area under the curve = 0.887 vs. 0.795, P < 0.001). At the per-patient level, the SSF2 group also demonstrated the highest diagnostic performance.

CONCLUSION:

The SSF2 algorithm significantly improved CCTA image quality and enhanced its diagnostic performance for evaluating stenosis severity and CT-FFR calculations.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Angiografia Coronária / Estenose Coronária / Reserva Fracionada de Fluxo Miocárdico / Angiografia por Tomografia Computadorizada Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Radiol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: IE / IRELAND / IRLANDA

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Angiografia Coronária / Estenose Coronária / Reserva Fracionada de Fluxo Miocárdico / Angiografia por Tomografia Computadorizada Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Radiol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: IE / IRELAND / IRLANDA