Your browser doesn't support javascript.
loading
A microfluidic ratiometric electrochemical aptasensor for highly sensitive and selective detection of 3,3',4,4'-tetrachlorobiphenyl.
Ji, Zhiheng; Wang, Dou; Wang, Juan.
Afiliação
  • Ji Z; Shanghai Key Laboratory of Materials Protection and Advanced Materials in Electric Power, Shanghai University of Electric Power, Shanghai 200090, China. wangjuan@shiep.edu.cn.
  • Wang D; Shanghai Key Laboratory of Materials Protection and Advanced Materials in Electric Power, Shanghai University of Electric Power, Shanghai 200090, China. wangjuan@shiep.edu.cn.
  • Wang J; Shanghai Key Laboratory of Materials Protection and Advanced Materials in Electric Power, Shanghai University of Electric Power, Shanghai 200090, China. wangjuan@shiep.edu.cn.
Anal Methods ; 16(25): 4160-4167, 2024 Jun 27.
Article em En | MEDLINE | ID: mdl-38874006
ABSTRACT
This study proposes a strategy using a microfluidic ratiometric electrochemical aptasensor to detect PCB77 with excellent sensitivity and specificity. This sensing platform combines a microfluidic chip, a wireless integrated circuit system for aptamer-based electrochemical detection, and a mobile phone control terminal for parameter configuration, identification, observation, and wireless data transfer. The sensing method utilizes a cDNA (MB-COOH-cDNA-SH) that is labelled with the redox probe Methylene Blue (MB) at the 5' end and has a thiol group at the 3' end. Additionally, it utilizes a single strand PCB aptamer that has been modified with ferrocenes at the 3' end (aptamer-Fc). Through gold-thiol binding, the labelled probe of MB-COOH-cDNA-SH was self-assembled onto the surface of an Au/Nb2CTx/GO modified electrode. On exposure to aptamer-Fc, it will hybridize with MB-COOH-cDNA-SH to form a stable double-stranded structure on the electrode surface. When PCB77 is present, aptamer-Fc binds specifically to the target, enabling the double-stranded DNA to unwind. Such variation caused changes in the differential pulse voltammetry (DPV) peak currents of both MB and Fc. A substantial improvement is observed in the ratio between the two DPV peaks. Under the optimum experimental conditions, this assay has a response that covers the 0.0001 to 1000 ng mL-1 PCB77 concentration range, and the detection limit is 1.56 × 10-5 ng mL-1. The integration of a ratiometric electrochemical aptasensor with designed microfluidic and integrated devices in this work is an innovative and promising approach that offers an efficient platform for on-site applications.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Bifenilos Policlorados / Aptâmeros de Nucleotídeos / Técnicas Eletroquímicas Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Bifenilos Policlorados / Aptâmeros de Nucleotídeos / Técnicas Eletroquímicas Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China