Your browser doesn't support javascript.
loading
CRISPR/Cas9-based engineered Escherichia coli biosensor for sensitive and specific detection of Cd(II) in drinking water.
Wei, Yijun; Shi, Danyang; Chen, Tianjiao; Zhou, Shuqing; Yang, Zhongwei; Li, Haibei; Yang, Dong; Li, Junwen; Jin, Min.
Afiliação
  • Wei Y; Military Medical Sciences Academy, Academy of Military Sciences, China.
  • Shi D; Military Medical Sciences Academy, Academy of Military Sciences, China.
  • Chen T; Military Medical Sciences Academy, Academy of Military Sciences, China.
  • Zhou S; Military Medical Sciences Academy, Academy of Military Sciences, China.
  • Yang Z; Military Medical Sciences Academy, Academy of Military Sciences, China.
  • Li H; Military Medical Sciences Academy, Academy of Military Sciences, China.
  • Yang D; Military Medical Sciences Academy, Academy of Military Sciences, China.
  • Li J; Military Medical Sciences Academy, Academy of Military Sciences, China.
  • Jin M; Military Medical Sciences Academy, Academy of Military Sciences, China. Electronic address: jinminzh@126.com.
Chemosphere ; 362: 142607, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38876330
ABSTRACT
Cadmium (Cd) is a ubiquitous pollutant that poses a potential threat to human health. Monitoring Cd(II) in drinking water has significant implications for preventing potential threats of Cd(II) to human. However, the weak signal output and response to nontarget interference limit the detection of Cd(II) using bacterial biosensors. In this study, to enable sensitive and specific detection of Cd(II) in water, a stable whole-cell biosensor, K12-PMP-luxCDABE-△cysI, was constructed in a dual-promoter mode by fusing the mercury promoter Pmer, regulatory gene merR(m), and luciferase gene luxCDABE into the E.coli chromosome based on CRISPR/Cas9 gene editing technology. By knocking out the cadmium-resistance-gene cysI, the sensitivity of the biosensor to Cd(II) was further enhanced. The constructed E. coli biosensor K12-PMP-luxCDABE-△cysI exhibited good nonlinear responses to 0.005-2 mg/L Cd(II). Notably, among the three constructed E. coli biosensor, it exhibited the strongest fluorescence intensity, with the limit of detection meeting the allowable limit for Cd(II) in drinking water. Simultaneously, it could specifically detect Cd(II). Nontarget metal ions, such as Zn(II), Hg(II), and Pb(II), did not affect its performance. Furthermore, it exhibited superior performance in detecting Cd(II) in real drinking water samples by avoiding background interference, and showed excellent stability with the relative standard deviation under 5%. Thus, K12-PMP-luxCDABE-△cysI holds promise as a potential tool for the detection of Cd(II) in drinking water.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Água Potável / Cádmio / Técnicas Biossensoriais / Escherichia coli / Sistemas CRISPR-Cas Idioma: En Revista: Chemosphere Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Água Potável / Cádmio / Técnicas Biossensoriais / Escherichia coli / Sistemas CRISPR-Cas Idioma: En Revista: Chemosphere Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China