Your browser doesn't support javascript.
loading
Microsphere lens array embedded microfluidic chip for SERS detection with simultaneous enhancement of sensitivity and stability.
Dong, Zhenyong; Liu, Xiaoxian; Zhou, Song; Zhu, Yifan; Chen, Jin; Liu, Yukai; Ren, Xiao; Lu, Yan-Qing; Xiao, Rui; Wang, Guanghui.
Afiliação
  • Dong Z; College of Engineering and Applied Sciences, Nanjing University, Nanjing, 210093, PR China; Key Laboratory of Intelligent Optical Sensing and Integration of the Ministry of Education, Nanjing University, Nanjing, 210009, PR China.
  • Liu X; College of Engineering and Applied Sciences, Nanjing University, Nanjing, 210093, PR China; Key Laboratory of Intelligent Optical Sensing and Integration of the Ministry of Education, Nanjing University, Nanjing, 210009, PR China; State Key Laboratory of Pathogen and Biosecurity, Beijing Institute o
  • Zhou S; Jiangsu Key Laboratory of Advanced Manufacturing Technology, Faculty of Mechanical and Material Engineering, Huaiyin Institute of Technology, Huai'an, 223003, PR China.
  • Zhu Y; College of Engineering and Applied Sciences, Nanjing University, Nanjing, 210093, PR China; Key Laboratory of Intelligent Optical Sensing and Integration of the Ministry of Education, Nanjing University, Nanjing, 210009, PR China.
  • Chen J; State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China.
  • Liu Y; College of Engineering and Applied Sciences, Nanjing University, Nanjing, 210093, PR China; Key Laboratory of Intelligent Optical Sensing and Integration of the Ministry of Education, Nanjing University, Nanjing, 210009, PR China.
  • Ren X; College of Engineering and Applied Sciences, Nanjing University, Nanjing, 210093, PR China; Key Laboratory of Intelligent Optical Sensing and Integration of the Ministry of Education, Nanjing University, Nanjing, 210009, PR China.
  • Lu YQ; College of Engineering and Applied Sciences, Nanjing University, Nanjing, 210093, PR China. Electronic address: yqlu@nju.edu.cn.
  • Xiao R; State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China. Electronic address: ruixiao203@163.com.
  • Wang G; College of Engineering and Applied Sciences, Nanjing University, Nanjing, 210093, PR China; Key Laboratory of Intelligent Optical Sensing and Integration of the Ministry of Education, Nanjing University, Nanjing, 210009, PR China; Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing Unive
Biosens Bioelectron ; 261: 116505, 2024 Oct 01.
Article em En | MEDLINE | ID: mdl-38885536
ABSTRACT
Surface enhanced Raman spectroscopy (SERS) utilizes the fingerprint features of molecular vibrations to identify and detect substances. However, in traditional single focus excitation scenarios, its signal collection efficiency of the objective is restricted. Furthermore, the uneven distribution of samples on the SERS substrate would result in poor signal stability, while the excitation power is limited to avoid sample damage. SERS detection system always requires precise adjustment of focal length and spot size, making it difficult for point-of-care testing applications. Here, we proposed a SERS microfluidic chip with barium titanate microspheres array (BTMA) embedded using vacuum self-assembled hot-pressing method for SERS detection with simultaneous enhancement of sensitivity and stability. Due to photonic nano-jets and directional antenna effects, high index microspheres are perfect micro-lens for effective light focusing and signal collecting. The BTMA can not only disperse excitation beam into an array of focal points covering the target uniformly with very low signal fluctuation, but enlarge the power threshold for higher signal intensity. We conducted a proof-of-principle experiment on chip for the detection of bacteria with immuno-magnetic tags and immuno-SERS tags. Together with magnetic and ultrasonic operations, the target bacteria in the flow were evenly congregated on the focal plane of BTMA. It demonstrated a limit of detection of 5 cells/mL, excellent signal reproducibility (error∼4.84%), and excellent position tolerance of 500 µm in X-Y plane (error∼5.375%). It can be seen that BTMA-SERS microfluidic chip can effectively solve the contradiction between sensitivity and stability in SERS detection.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Técnicas Biossensoriais / Dispositivos Lab-On-A-Chip / Microesferas Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Técnicas Biossensoriais / Dispositivos Lab-On-A-Chip / Microesferas Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2024 Tipo de documento: Article