Your browser doesn't support javascript.
loading
Effects of monopolar pulsed-capacitive dielectric radiofrequency diathermy in patients with chronic low back pain: a randomised clinical trial.
Lara-Palomo, Inmaculada Carmen; Capel-Alcaraz, Ana María; García-López, Héctor; Castro-Sánchez, Adelaida María; Albornoz-Cabello, Manuel.
Afiliação
  • Lara-Palomo IC; Department of Nursing, Physical Therapy and Medicine, University of Almeria, Ctra. Sacramento s/n La Cañada de San Urbano, 04120, Almería, Spain. ilp813@ual.es.
  • Capel-Alcaraz AM; Department of Nursing, Physical Therapy and Medicine, University of Almeria, Ctra. Sacramento s/n La Cañada de San Urbano, 04120, Almería, Spain.
  • García-López H; Department of Nursing, Physical Therapy and Medicine, University of Almeria, Ctra. Sacramento s/n La Cañada de San Urbano, 04120, Almería, Spain.
  • Castro-Sánchez AM; Department of Nursing, Physical Therapy and Medicine, University of Almeria, Ctra. Sacramento s/n La Cañada de San Urbano, 04120, Almería, Spain.
  • Albornoz-Cabello M; Department of Physiotherapy, University of Seville, 41004, Seville, Spain.
Sci Rep ; 14(1): 14059, 2024 06 18.
Article em En | MEDLINE | ID: mdl-38890440
ABSTRACT
Monopolar capacitive diathermy is a physiotherapy technique that uses high-frequency currents to generate heat in deep tissues. This heat can have several therapeutic effects, especially in the treatment of chronic low back pain (CLBP), however, until now there is little evidence of this type of diathermy. The purpose was to evaluate the efficacy of a pulsed monopolar dielectric radiofrequency diathermy (PRF)-capacitive type versus simulated treatment on symptomatology of patients with CLBP. A single-blind randomised controlled trial was conducted. Sixty patients with CLBP were randomly assigned to a PRF-capacitive or a simulated treatment group. All participants received 3 sessions per week for 3 weeks. Disability, pain intensity, movement phobia, lumbar anteflexion, quality of life, and sleep quality were assessed at baseline, after treatment, and at two months. The application of 9 sessions of PRF-capacitive showed significant improvements compared to simulated therapy during the entire follow-up for disability (F = 26.99, p < 0.001), pain intensity (F = 0.550, p < 0.001), the quality of life components of physical function (F = 0.780, p < 0.001), social function (F = 0.780, p < 0.001) and mental health (F = 0.858, p = 0.003) and for sleep duration (F = 0.863, p = 0.004).
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Qualidade de Vida / Dor Lombar / Diatermia / Dor Crônica Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Espanha País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Qualidade de Vida / Dor Lombar / Diatermia / Dor Crônica Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Espanha País de publicação: Reino Unido