Your browser doesn't support javascript.
loading
Multi-residue determination of biocides in dairy products and slurry feed using QuEChERS extraction and liquid chromatography combined with high resolution mass spectrometry (LC-ESI-QOrbitrap™-MS).
Dos Santos, Ingrid D; Zomer, Paul; Pizzutti, Ionara R; Wagner, Roger; Mol, Hans.
Afiliação
  • Dos Santos ID; Wageningen Food Safety Research, part of Wageningen University & Research, Wageningen, the Netherlands; Department of Food Technology and Science, Federal University of Santa Maria, Roraima Avenue 1000, Camobi, Rio Grande do Sul state, Santa Maria 97105-900, RS, Brazil. Electronic address: ingri
  • Zomer P; Wageningen Food Safety Research, part of Wageningen University & Research, Wageningen, the Netherlands.
  • Pizzutti IR; Center of Research and Analysis of Contaminants (CEPARC), Department of Chemistry, Roraima Avenue 1000, Camobi, Rio Grande do Sul state, Santa Maria 97105-900, RS, Brazil.
  • Wagner R; Department of Food Technology and Science, Federal University of Santa Maria, Roraima Avenue 1000, Camobi, Rio Grande do Sul state, Santa Maria 97105-900, RS, Brazil.
  • Mol H; Wageningen Food Safety Research, part of Wageningen University & Research, Wageningen, the Netherlands.
Food Chem ; 457: 140117, 2024 Jun 15.
Article em En | MEDLINE | ID: mdl-38905841
ABSTRACT
Given that the determination of biocides in food and feed is currently not routinely done, more information on these compounds is useful for consumer's safety. This work describes a sensitive and reliable method for quantitative analysis of a wide range of biocides in dairy products and slurry feed. The method comprises acetate-buffered QuEChERS extraction without clean-up. Analyses were performed by LC-Q-Orbitrap™-MS and a full-scan acquisition event without fragmentation was followed by five fragmentation events (data-independent acquisition-DIA). The quantitative validation was performed according to SANTE/11312/2021 at 10, 50 and 200 ng g-1 spiking levels, and the results showed that the vast majority of the compounds met the criteria for trueness and precision. The LOQ was 10 ng g-1 for the majority of biocides depending on the matrix. The method was successfully applied to quantify biocides in dairy products and feed.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Food Chem Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Food Chem Ano de publicação: 2024 Tipo de documento: Article