Your browser doesn't support javascript.
loading
New objective simple evaluation methods of amyloid PET/CT using whole-brain histogram and Top20%-Map.
Okuyama, Chio; Higashi, Tatsuya; Ishizu, Koichi; Oishi, Naoya; Kusano, Kuninori; Ito, Miki; Kagawa, Shinya; Okina, Tomoko; Suzuki, Norio; Hasegawa, Hiroshi; Nagahama, Yasuhiro; Watanabe, Hiroyuki; Ono, Masahiro; Yamauchi, Hiroshi.
Afiliação
  • Okuyama C; Clinical Research Center, Shiga General Hospital, Moriyama, Japan. okuyama@res.med.shiga-pref.jp.
  • Higashi T; Clinical Research Center, Shiga General Hospital, Moriyama, Japan. higashi.tatsuya@qst.go.jp.
  • Ishizu K; Department of Molecular Imaging and Theranostics, National Institute of Quantum Science and Technology, Chiba, Japan. higashi.tatsuya@qst.go.jp.
  • Oishi N; Clinical Research Center, Shiga General Hospital, Moriyama, Japan.
  • Kusano K; Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
  • Ito M; Human Brain Research Center, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
  • Kagawa S; Clinical Research Center, Shiga General Hospital, Moriyama, Japan.
  • Okina T; Department of Radiology, Shiga General Hospital, Moriyama, Japan.
  • Suzuki N; Clinical Research Center, Shiga General Hospital, Moriyama, Japan.
  • Hasegawa H; Department of Radiology, Shiga General Hospital, Moriyama, Japan.
  • Nagahama Y; Clinical Research Center, Shiga General Hospital, Moriyama, Japan.
  • Watanabe H; Department of Neurology, Shiga General Hospital, Moriyama, Japan.
  • Ono M; Department of Neurology, Shiga General Hospital, Moriyama, Japan.
  • Yamauchi H; Department of Neurology, Shiga General Hospital, Moriyama, Japan.
Ann Nucl Med ; 2024 Jun 22.
Article em En | MEDLINE | ID: mdl-38907835
ABSTRACT

OBJECTIVE:

This study aims to assess the utility of newly developed objective methods for the evaluation of intracranial abnormal amyloid deposition using PET/CT histogram without use of cortical ROI analyses.

METHODS:

Twenty-five healthy volunteers (HV) and 38 patients with diagnosed or suspected dementia who had undergone 18F-FPYBF-2 PET/CT were retrospectively included in this study. Out of them, 11C-PiB PET/CT had been also performed in 13 subjects. In addition to the conventional methods, namely visual judgment and quantitative analyses using composed standardized uptake value ratio (comSUVR), the PET images were also evaluated by the following new parameters the skewness and the mode-to-mean ratio (MMR) obtained from the histogram of the brain parenchyma; Top20%-map highlights the areas with high tracer accumulation occupying 20% volume of the total brain parenchymal on the individual's CT images. We evaluated the utility of the new methods using histogram compared with the visual assessment and comSUVR. The results of these new methods between 18F-FPYBF-2 and 11C-PiB were also compared in 13 subjects.

RESULTS:

In visual analysis, 32, 9, and 22 subjects showed negative, border, and positive results, and composed SUVR in each group were 1.11 ± 0.06, 1.20 ± 0.13, and 1.48 ± 0.18 (p < 0.0001), respectively. Visually positive subjects showed significantly low skewness and high MMR (p < 0.0001), and the Top20%-Map showed the presence or absence of abnormal deposits clearly. In comparison between the two tracers, visual evaluation was all consistent, and the ComSUVR, the skewness, the MMR showed significant good correlation. The Top20%-Maps showed similar pattern.

CONCLUSIONS:

Our new methods using the histogram of the brain parenchymal accumulation are simple and suitable for clinical practice of amyloid PET, and Top20%-Map on the individual's brain CT can be of great help for the visual assessment.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Ann Nucl Med Assunto da revista: MEDICINA NUCLEAR Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão