Your browser doesn't support javascript.
loading
Reactive Species Risk Assessment Using Optimized HET-CAM Safety Evaluation of Feed Gas-Modified Gas Plasma Technology and Anticancer Drugs.
Berner, Julia; Herold, Luise; Martinet, Alice; Miebach, Lea; von Woedke, Thomas; Weltmann, Klaus-Dieter; Emmert, Steffen; Boeckmann, Lars; Bekeschus, Sander.
Afiliação
  • Berner J; Clinic and Policlinic for Dermatology and Venerology, Rostock University Medical Center, Strempelstr. 13, 18057 Rostock, Germany.
  • Herold L; ZIK Plasmatis, Leibniz Institute for Plasma Science and Technology (INP), a Member of the Leibniz Health Technologies Research Alliance, Felix-Hausdorff-Str. 2, 17489 Greifswald, Germany.
  • Martinet A; ZIK Plasmatis, Leibniz Institute for Plasma Science and Technology (INP), a Member of the Leibniz Health Technologies Research Alliance, Felix-Hausdorff-Str. 2, 17489 Greifswald, Germany.
  • Miebach L; Department of Oral, Maxillofacial, and Plastic Surgery, Greifswald University Medical Center, Ferdinand-Sauerbruch-Str., 17475 Greifswald, Germany.
  • von Woedke T; Clinic and Policlinic for Dermatology and Venerology, Rostock University Medical Center, Strempelstr. 13, 18057 Rostock, Germany.
  • Weltmann KD; ZIK Plasmatis, Leibniz Institute for Plasma Science and Technology (INP), a Member of the Leibniz Health Technologies Research Alliance, Felix-Hausdorff-Str. 2, 17489 Greifswald, Germany.
  • Emmert S; ZIK Plasmatis, Leibniz Institute for Plasma Science and Technology (INP), a Member of the Leibniz Health Technologies Research Alliance, Felix-Hausdorff-Str. 2, 17489 Greifswald, Germany.
  • Boeckmann L; ZIK Plasmatis, Leibniz Institute for Plasma Science and Technology (INP), a Member of the Leibniz Health Technologies Research Alliance, Felix-Hausdorff-Str. 2, 17489 Greifswald, Germany.
  • Bekeschus S; ZIK Plasmatis, Leibniz Institute for Plasma Science and Technology (INP), a Member of the Leibniz Health Technologies Research Alliance, Felix-Hausdorff-Str. 2, 17489 Greifswald, Germany.
ACS Appl Mater Interfaces ; 16(27): 34480-34495, 2024 Jul 10.
Article em En | MEDLINE | ID: mdl-38923892
ABSTRACT
Clinical therapies, including dermatology and oncology, require safe application. In vitro experiments allow only limited conclusions about in vivo effects, while animal studies in, e.g., rodents have ethical constraints at a large scale. Chicken embryos lack pain reception until day 15 postfertilization, making the in ovo model a suitable alternative to in vivo safety assessment. In addition, the hen's egg test on chorioallantoic membrane assay allows irritation potential analysis for topical treatments, but standardized analysis has been limited so far. Medical gas plasma is a topical, routine, approved dermatology treatment. Recent work suggests the potential of this technology in oncology. Its main mode of action is the release of various reactive species simultaneously. Intriguingly, varying plasma feed gas compositions generates customized reactive species profiles previously shown to be optimized for specific applications, such as skin cancer treatment. To support clinical implications, we developed a novel chicken embryo CAM scoring and study scheme and employed the model to analyze 16 different plasma feed gas settings generated by the atmospheric pressure plasmajet kINPen, along with common anticancer drugs (e.g., cisplatin) and physiological mediators (e.g., VEGF). Extensive gas- and liquid-phase plasma reactive species profiling was done and was found to have a surprisingly low correlation with irritation potential parameters. Despite markedly different reactive species patterns, feed gas-modulated kINPen plasma was equally tolerated compared to standard argon plasma. CAM irritation with gas plasmas but not anticancer agents was reversed 48 h after treatment, underlining the only temporary tissue effects of medical gas plasma. Our results indicate a safe therapeutic application of reactive species.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Membrana Corioalantoide / Gases em Plasma / Antineoplásicos Limite: Animals / Humans Idioma: En Revista: ACS Appl Mater Interfaces Assunto da revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Membrana Corioalantoide / Gases em Plasma / Antineoplásicos Limite: Animals / Humans Idioma: En Revista: ACS Appl Mater Interfaces Assunto da revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha