Your browser doesn't support javascript.
loading
Pixel-Wise Interstitial Lung Disease Interval Change Analysis: A Quantitative Evaluation Method for Chest Radiographs Using Weakly Supervised Learning.
Park, Subin; Kim, Jong Hee; Woo, Jung Han; Park, So Young; Cha, Yoon Ki; Chung, Myung Jin.
Afiliação
  • Park S; Department of Health Sciences es and Technology, SAIHST, Sungkyunkwan University, Seoul 06351, Republic of Korea.
  • Kim JH; Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 0631, Republic of Korea.
  • Woo JH; Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 0631, Republic of Korea.
  • Park SY; Department of Health Sciences es and Technology, SAIHST, Sungkyunkwan University, Seoul 06351, Republic of Korea.
  • Cha YK; Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 0631, Republic of Korea.
  • Chung MJ; Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 0631, Republic of Korea.
Bioengineering (Basel) ; 11(6)2024 Jun 02.
Article em En | MEDLINE | ID: mdl-38927798
ABSTRACT
Interstitial lung disease (ILD) is characterized by progressive pathological changes that require timely and accurate diagnosis. The early detection and progression assessment of ILD are important for effective management. This study introduces a novel quantitative evaluation method utilizing chest radiographs to analyze pixel-wise changes in ILD. Using a weakly supervised learning framework, the approach incorporates the contrastive unpaired translation model and a newly developed ILD extent scoring algorithm for more precise and objective quantification of disease changes than conventional visual assessments. The ILD extent score calculated through this method demonstrated a classification accuracy of 92.98% between ILD and normal classes. Additionally, using an ILD follow-up dataset for interval change analysis, this method assessed disease progression with an accuracy of 85.29%. These findings validate the reliability of the ILD extent score as a tool for ILD monitoring. The results of this study suggest that the proposed quantitative method may improve the monitoring and management of ILD.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Bioengineering (Basel) Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Bioengineering (Basel) Ano de publicação: 2024 Tipo de documento: Article