Factors affecting radiation dose, radiation exposure time and procedural time in arterial embolization for active hemorrhage.
Ghosn, Youssef; Khdhir, Mihran; Jabbour, Yara; Dushfunian, David; Kobeissi, Iyad; Abbas, Nada; Akkari, Chantal; Kahwaji, Eva-Maria; Muallem, Nadim.
Afiliação
  • Ghosn Y; Department of Diagnostic Radiology, American University of Beirut, Riad El-Solh, P.O.Box 11-0236, Beirut, 1107 2020, Lebanon.
  • Khdhir M; Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, USA.
  • Jabbour Y; Department of Diagnostic Radiology, American University of Beirut, Riad El-Solh, P.O.Box 11-0236, Beirut, 1107 2020, Lebanon.
  • Dushfunian D; Faculty of Medicine, American University of Beirut, Beirut, Lebanon.
  • Kobeissi I; Faculty of Medicine, American University of Beirut, Beirut, Lebanon.
  • Abbas N; American University of Beirut, Beirut, Lebanon.
  • Akkari C; Department of Diagnostic Radiology, American University of Beirut, Riad El-Solh, P.O.Box 11-0236, Beirut, 1107 2020, Lebanon.
  • Kahwaji EM; Faculty of Health Science, American University of Berirut, Beirut, Lebanon.
  • Muallem N; Department of Diagnostic Radiology, American University of Beirut, Riad El-Solh, P.O.Box 11-0236, Beirut, 1107 2020, Lebanon. nm53@aub.edu.lb.
Emerg Radiol ; 31(5): 641-652, 2024 Oct.
Article em En | MEDLINE | ID: mdl-38955874
ABSTRACT

PURPOSE:

To evaluate patient and procedure-related factors contributing to the radiation dose, cumulative fluoroscopy time (CFT), and procedural time (PT) of Arterial Embolization (AE) for suspected active bleeding.

METHODS:

Data on patients who underwent AE for suspected bleeding was retrospectively gathered between January 2019 and April 2022. Data collected included the dependent variables consisting of dose-area product (DAP), CFT, PT, and independent variables consisting of demographic, bleeding-specific, and procedure-specific parameters. All statistical computations were performed in SPSS statistics. The alpha value was set at 0.05.

RESULTS:

Data from a total of 148 AE were collected with an average patient's age of 61.06 ± 21.57 years. Higher DAP was independently associated with male sex (p < 0.002), age ranges between 46 and 65 years (p = 0.019) and > 66 years (p = 0.027), BMI above 30 (p = 0.016), attending with less than 10 years of experience (p = 0.01), and bleeding in the abdomen and pelvis (p = 0.027). Longer CFT was independently associated with attending with less than 10 years of experience (p < 0.001), having 2 (p = 0.004) or > 3 (p = 0.005) foci of bleed, and age between 46 and 65 years (p = 0.007) and ≥ 66 years (p = 0.017). Longer PT was independently associated with attending with less than 10 years of experience (p < 0.001) and having 2 (p = 0.014) or > 3 (p = 0.005) foci of bleed.

CONCLUSION:

The interventionist experience influenced radiation dose, CFT and PT. Dose was also affected by patients' sex, age, BMI, as well as bleeding location. CFT was also affected by patients' age, and both CFT and PT were also affected by the number of bleeding foci. These findings highlight the multifaceted factors that affect radiation dose and procedural time, emphasizing the importance of interventionist expertise, patient's age, sex, BMI, location and number of bleeds.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Exposição à Radiação / Embolização Terapêutica / Hemorragia Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Emerg Radiol / Emerg. radiol / Emergency radiology Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Líbano País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Exposição à Radiação / Embolização Terapêutica / Hemorragia Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Emerg Radiol / Emerg. radiol / Emergency radiology Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Líbano País de publicação: Estados Unidos