Your browser doesn't support javascript.
loading
Influence of examiner calibration on clinical and mri diagnosis of temporomandibular joint disc displacement: a systematic review and meta-analysis.
Maracci, Lucas M; Savegnago, Gleica D O; Antoniazzi, Raquel P; Marquezan, Mariana; Silva, Tatiana B; Liedke, Gabriela S.
Afiliação
  • Maracci LM; Dental Sciences Post-Graduation Program, Federal University of Santa Maria, Santa Maria, RS, Brazil.
  • Savegnago GDO; Dental Sciences Post-Graduation Program, Federal University of Santa Maria, Santa Maria, RS, Brazil.
  • Antoniazzi RP; Department of Stomatology, Federal University of Santa Maria, Santa Maria, RS, Brazil.
  • Marquezan M; Department of Stomatology, Federal University of Santa Maria, Santa Maria, RS, Brazil.
  • Silva TB; Department of Restorative Dentistry, Federal University of Santa Maria, Santa Maria, RS, Brazil.
  • Liedke GS; Department of Stomatology, Federal University of Santa Maria, Santa Maria, RS, Brazil.
Article em En | MEDLINE | ID: mdl-38970385
ABSTRACT

OBJECTIVES:

This study aimed to verify the accuracy of clinical protocols for the diagnosis of disc displacement (DD) compared with magnetic resonance imaging (MRI), considering examiners' calibration.

METHODS:

PubMed, Cochrane (Central), Scopus, Web of Science, LILACS, Embase, Science Direct, Google Scholar, and DANS EASY Archive databases were searched. Two reviewers independently screened and selected the studies. A meta-analysis was conducted using the R Statistical software. Results are shown using sensitivity and specificity, and 95% confidence intervals.

RESULTS:

Of the 20 studies included in the systematic review, only 3 were classified as low risk of bias. Seventeen studies were included in the meta-analysis. Compared to MRI, clinical protocols showed overall sensitivity and specificity of 0.75 (0.63-0.83) and 0.73 (0.59-0.84) for DD diagnosis, respectively. For DD with reduction, sensitivity was 0.64 (0.48-0.77) and specificity was 0.72 (0.48-0.87). For DD without reduction, sensitivity was 0.58 (0.39-0.74) and specificity 0.93 (0.83-0.97). Only 8 studies reported examiner calibration when performing clinical and/or MRI evaluation; nevertheless, calibration showed a tendency to improve the diagnosis of DD.

CONCLUSION:

The sensitivity and specificity of clinical protocols in the diagnosis of DD are slightly below the recommended values, as well as the studies lack calibration of clinical and MRI examiners. Examiner calibration seems to improve the diagnosis of DD.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Dentomaxillofac Radiol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Dentomaxillofac Radiol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil