Your browser doesn't support javascript.
loading
Additive-manufactured paper-PMMA hybrid microfluidic chip for simultaneous monitoring of creatinine and pH in artificial urine.
Sheeraz, Asim Syed; Aiswarya, Edoth; Kumara, B N; Sonia, J; Rodrigues, Relisha Viyona; Sheikh, Nazmin; Vidyasagar, Sachin; Kunder, Rachana A; Elangovan, Selvakumar; Mohanty, Priti Sundar; Prasad, K Sudhakara.
Afiliação
  • Sheeraz AS; School of Biotechnology, KIIT (Deemed to be University), Bhubaneswar, Odisha, India. pritisundar.mohanty@kiitbiotech.ac.in.
  • Aiswarya E; Nanomaterial research laboratory (NMRL), Nano Division, Yenepoya Research Centre, Yenepoya (Deemed to be University), Deralakatte, Mangalore 575 018, India. ksprasadnair@yenepoya.edu.in.
  • Kumara BN; Nanomaterial research laboratory (NMRL), Nano Division, Yenepoya Research Centre, Yenepoya (Deemed to be University), Deralakatte, Mangalore 575 018, India. ksprasadnair@yenepoya.edu.in.
  • Sonia J; Nanomaterial research laboratory (NMRL), Nano Division, Yenepoya Research Centre, Yenepoya (Deemed to be University), Deralakatte, Mangalore 575 018, India. ksprasadnair@yenepoya.edu.in.
  • Rodrigues RV; Nanomaterial research laboratory (NMRL), Nano Division, Yenepoya Research Centre, Yenepoya (Deemed to be University), Deralakatte, Mangalore 575 018, India. ksprasadnair@yenepoya.edu.in.
  • Sheikh N; Nanomaterial research laboratory (NMRL), Nano Division, Yenepoya Research Centre, Yenepoya (Deemed to be University), Deralakatte, Mangalore 575 018, India. ksprasadnair@yenepoya.edu.in.
  • Vidyasagar S; Nanomaterial research laboratory (NMRL), Nano Division, Yenepoya Research Centre, Yenepoya (Deemed to be University), Deralakatte, Mangalore 575 018, India. ksprasadnair@yenepoya.edu.in.
  • Kunder RA; Nanomaterial research laboratory (NMRL), Nano Division, Yenepoya Research Centre, Yenepoya (Deemed to be University), Deralakatte, Mangalore 575 018, India. ksprasadnair@yenepoya.edu.in.
  • Elangovan S; School of Biotechnology, KIIT (Deemed to be University), Bhubaneswar, Odisha, India. pritisundar.mohanty@kiitbiotech.ac.in.
  • Mohanty PS; School of Biotechnology, KIIT (Deemed to be University), Bhubaneswar, Odisha, India. pritisundar.mohanty@kiitbiotech.ac.in.
  • Prasad KS; Nanomaterial research laboratory (NMRL), Nano Division, Yenepoya Research Centre, Yenepoya (Deemed to be University), Deralakatte, Mangalore 575 018, India. ksprasadnair@yenepoya.edu.in.
Analyst ; 149(15): 3882-3890, 2024 Jul 22.
Article em En | MEDLINE | ID: mdl-38973472
ABSTRACT
Nowadays, kidney dysfunction is a common health issue due to the modernized lifestyle. Even though medications are commercially available to treat kidney diseases, early diagnosis is crucial and challenging. Clinically, measuring urine creatinine and pH has gained significant interest as a way to diagnose kidney diseases early. In the present work, we attempted to develop a low-cost, robust, accurate and naked-eye colorimetric method to determine both creatinine levels and pH variations in artificial urine samples using a simple 3D-printed hybrid microfluidic device. Creatinine was detected by the incorporation of the traditional Jaffe test onto the hybrid paper-PMMA microfluidic device and pH (4-8) was measured by a simple anthocyanin test. Notably, the tests were established without employing any sophisticated or costly instrument clusters. The developed 3D-printed microfluidic probe showed a limit of detection (LOD) of 0.04 mM for creatinine over a concentration range of 1-10 mM, with a regression coefficient (R2) of 0.995 in laboratory conditions. Interestingly, the experimental data obtained with artificial urine exhibited a wide linear range from 0.1 mM to 5 mM under different pH values ranging from 4 to 8 in the presence of matrices commonly found in urine samples other than proteins, indicating the potential use of this method in pre-clinical analysis. Since the wide linear range of urine creatinine in artificial urine samples falls well below the clinically relevant concentrations in humans (0.07-0.27 mM), the developed lab-on-chip device is further suitable for clinical evaluation with proper ethical clearance. This 3D-printed hybrid microfluidic colorimetry-based creatinine detection and pH indicator platform can be beneficial in the healthcare sector due to the on-site testing capability, cost-effectiveness, ease of use, robustness, and instrument-free approach.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Papel / Polimetil Metacrilato / Creatinina / Limite de Detecção / Dispositivos Lab-On-A-Chip Limite: Humans Idioma: En Revista: Analyst Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Papel / Polimetil Metacrilato / Creatinina / Limite de Detecção / Dispositivos Lab-On-A-Chip Limite: Humans Idioma: En Revista: Analyst Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia