Your browser doesn't support javascript.
loading
Rapid analysis of untreated food samples by gel loading tip spray ionization mass spectrometry.
Rahman, Md Matiur; Wang, Shuanglong; Xu, Jiaquan; Zhang, Xiaoping; Zhang, Xinglei; Chingin, Konstantin.
Afiliação
  • Rahman MM; Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, 330013, People's Republic of China. matiurrahman@ecit.cn.
  • Wang S; Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, 330013, People's Republic of China.
  • Xu J; Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, 330013, People's Republic of China.
  • Zhang X; Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, 330013, People's Republic of China.
  • Zhang X; Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, 330013, People's Republic of China.
  • Chingin K; Jiangxi University of Traditional Chinese Medicine, Nanchang, People's Republic of China.
Anal Bioanal Chem ; 416(20): 4435-4445, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38981911
ABSTRACT
Rapid, efficient, versatile, easy-to-use, and non-expensive analytical approaches are globally demanded for food analysis. Many ambient ionization approaches based on electrospray ionization (ESI) have been developed recently for the rapid molecular characterization of food products. However, those approaches mainly suffer from insufficient signal duration for comprehensive chemical characterization by tandem MS analysis. Here, a commercially available disposable gel loading tip is used as a low-cost emitter for the direct ionization of untreated food samples. The most important advantages of our approach include high stability, and durability of the signal (> 10 min), low cost (ca. 0.1 USD per run), low sample and solvent consumption, prevention of tip clogging and discharge, operational simplicity, and potential for automation. Quantitative analysis of sulfapyridine, HMF (hydroxymethylfurfural), and chloramphenicol in real sample shows the limit-of-detection 0.1 µg mL-1, 0.005 µg mL-1, 0.01 µg mL-1; the linearity range 0.1-5 µg mL-1, 0.005-0.25 µg mL-1, 0.01-1 µg mL-1; and the linear fits R2 ≥ 0.980, 0.991, 0.986. Moreover, we show that tip-ESI can also afford sequential molecular ionization of untreated viscous samples, which is difficult to achieve by conventional ESI. We conclude that tip-ESI-MS is a versatile analytical approach for the rapid chemical analysis of untreated food samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas por Ionização por Electrospray / Limite de Detecção / Análise de Alimentos Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2024 Tipo de documento: Article País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas por Ionização por Electrospray / Limite de Detecção / Análise de Alimentos Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2024 Tipo de documento: Article País de publicação: Alemanha