Your browser doesn't support javascript.
loading
Py-GC-MS analysis for microplastics: Unlocking matrix challenges and sample recovery when analyzing wastewater for polypropylene and polystyrene.
Lykkemark, Jeanette; Mattonai, Marco; Vianello, Alvise; Gomiero, Alessio; Modugno, Francesca; Vollertsen, Jes.
Afiliação
  • Lykkemark J; Department of the Built Environment, Aalborg University, Aalborg, Denmark.
  • Mattonai M; Department of Chemistry and Industrial Chemistry, University of Pisa, Pisa, Italy; National Interuniversity Consortium of Materials Science and Technology, Italy. Electronic address: marco.mattonai@dcci.unipi.it.
  • Vianello A; Department of the Built Environment, Aalborg University, Aalborg, Denmark.
  • Gomiero A; NORCE Norwegian Research Centre AS, Norway; North Atlantic Microplastic Centre (NAMC), Norway.
  • Modugno F; Department of Chemistry and Industrial Chemistry, University of Pisa, Pisa, Italy; North Atlantic Microplastic Centre (NAMC), Norway.
  • Vollertsen J; Department of the Built Environment, Aalborg University, Aalborg, Denmark; North Atlantic Microplastic Centre (NAMC), Norway.
Water Res ; 261: 122055, 2024 Sep 01.
Article em En | MEDLINE | ID: mdl-38996726
ABSTRACT
Matrix interference and recovery when using pyrolysis gas chromatography (Py-GC-MS) to analyze wastewater for polystyrene (PS) and polypropylene (PP) microplastics (MP) was studied. Raw wastewater underwent a sample preparation train commonly applied for such matrix. The train consisted of six discrete steps to reduce the organic matter content without affecting MP in the sample. One large wastewater sample was collected, homogenized, and subdivided into 21 subsamples. Three samples were analyzed without further sample preparation. The remaining samples were divided in sets of three, and each set underwent an increasing number of steps of the procedure, up to the last set, which underwent the full treatment. The matrix effect on the determination of PS and PP was statistically evaluated by comparing in-matrix and external calibration curves at each step. Recovery of MP was assessed after each step by adding deuterated PS to the samples. A main finding was that there was no significant matrix effect for these polymers throughout the preparation train, suggesting that matrix components did not interfere with the analytical method. However, a significant loss of polymer mass was found between the steps, which may result in MPs falling below detection limits. Therefore, Py-GC-MS could be used for MP quantification before analysis by other techniques which require more extensive matrix removal. A downside of this approach is that analyzing such samples without matrix reduction will increase the need for instrumental maintenance.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polipropilenos / Poliestirenos / Poluentes Químicos da Água / Águas Residuárias / Microplásticos / Cromatografia Gasosa-Espectrometria de Massas Idioma: En Revista: Water Res Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Dinamarca País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polipropilenos / Poliestirenos / Poluentes Químicos da Água / Águas Residuárias / Microplásticos / Cromatografia Gasosa-Espectrometria de Massas Idioma: En Revista: Water Res Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Dinamarca País de publicação: Reino Unido