Your browser doesn't support javascript.
loading
Using Resistance-Band Tests to Evaluate Trunk Muscle Strength in Chronic Low Back Pain: A Test-Retest Reliability Study.
Franco-López, Francisco; Durkalec-Michalski, Krzysztof; Díaz-Morón, Jesús; Higueras-Liébana, Enrique; Hernández-Belmonte, Alejandro; Courel-Ibáñez, Javier.
Afiliação
  • Franco-López F; Department of Physical Activity and Sport, Faculty of Sport Sciences, University of Murcia, 30720 Murcia, Spain.
  • Durkalec-Michalski K; Department of Sports Dietetics, Poznan University of Physical Education, 61-871 Poznan, Poland.
  • Díaz-Morón J; SANO Sport Center, el Toyo, 04131 Almería, Spain.
  • Higueras-Liébana E; Department of Physical Activity and Sport, Faculty of Sport Sciences, University of Murcia, 30720 Murcia, Spain.
  • Hernández-Belmonte A; Department of Physical Activity and Sport, Faculty of Sport Sciences, University of Murcia, 30720 Murcia, Spain.
  • Courel-Ibáñez J; Department of Physical Education and Sports, Faculty of Education and Sport Sciences, University of Granada, 52005 Melilla, Spain.
Sensors (Basel) ; 24(13)2024 Jun 25.
Article em En | MEDLINE | ID: mdl-39000910
ABSTRACT
Exercise is a front-line intervention to increase functional capacity and reduce pain and disability in people with low strength levels or disorders. However, there is a lack of validated field-based tests to check the initial status and, more importantly, to control the process and make tailored adjustments in load, intensity, and recovery. We aimed to determine the test-retest reliability of a submaximal, resistance-band test to evaluate the strength of the trunk stability muscles using a portable force sensor in middle-aged adults (48 ± 13 years) with medically diagnosed chronic low back pain and healthy peers (n = 35). Participants completed two submaximal progressive tests of two resistance-band exercises (unilateral row and Pallof press), consisting of 5 s maintained contraction, progressively increasing the load. The test stopped when deviation from the initial position by compensation movements occurred. Trunk muscle strength (CORE muscles) was monitored in real time using a portable force sensor (strain gauge). Results revealed that both tests were highly reliable (intra-class correlation [ICC] > 0.901) and presented low errors and coefficients of variation (CV) in both groups. In particular, people with low back pain had errors of 14-19 N (CV = 9-12%) in the unilateral row test and 13-19 N (CV = 8-12%) in the Pallof press. No discomfort or pain was reported during or after the tests. These two easy-to-use and technology-based tests result in a reliable and objective screening tool to evaluate the strength and trunk stability in middle-aged adults with chronic low back pain, considering an error of measurement < 20 N. This contribution may have an impact on improving the individualization and control of rehabilitation or physical training in people with lumbar injuries or disorders.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dor Lombar / Força Muscular Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dor Lombar / Força Muscular Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Espanha