Radioactivity estimation of radioactive hotspots using a Compton camera and derivation of dose rates in the surrounding environment.
Appl Radiat Isot
; 212: 111421, 2024 Oct.
Article
em En
| MEDLINE
| ID: mdl-39002295
ABSTRACT
At the Fukushima Daiichi Nuclear Power Station, radiation sources released in the accident were deposited on various equipment and building structures. During decommissioning, it is crucial to understand the distribution of radiation sources and ambient dose equivalent rates to reduce worker exposure and implement detailed work planning. In this study, the author introduces a method for visualizing radiation sources, estimates their radioactivity using a Compton camera, and derives the dose rate around the radiation sources. In the demonstration test, the Compton camera was used to visualize radioactive hotspots caused by 137Cs radiation sources deposited in the outdoor environment and estimated the radioactivity. Furthermore, the dose rate around the hotspots was calculated from the estimated radioactivity, which confirmed that the calculated dose rate correlated with the dose rate measured using a survey meter. This approach is novel, where a series of analyses were conducted using the Compton camera to visualize radioactive hotspots, estimate the radioactivity, and derive the dose rate in the surrounding environment.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Idioma:
En
Revista:
Appl Radiat Isot
Assunto da revista:
MEDICINA NUCLEAR
/
SAUDE AMBIENTAL
Ano de publicação:
2024
Tipo de documento:
Article
País de publicação:
Reino Unido