Your browser doesn't support javascript.
loading
Absolute values of regional ventilation-perfusion mismatch in patients with ARDS monitored by electrical impedance tomography and the role of dead space and shunt compensation.
Leali, Marco; Marongiu, Ines; Spinelli, Elena; Chiavieri, Valentina; Perez, Joaquin; Panigada, Mauro; Grasselli, Giacomo; Mauri, Tommaso.
Afiliação
  • Leali M; Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
  • Marongiu I; Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
  • Spinelli E; Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
  • Chiavieri V; Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
  • Perez J; Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
  • Panigada M; Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
  • Grasselli G; Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
  • Mauri T; Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
Crit Care ; 28(1): 241, 2024 Jul 15.
Article em En | MEDLINE | ID: mdl-39010228
ABSTRACT

BACKGROUND:

Assessment of regional ventilation/perfusion (V'/Q) mismatch using electrical impedance tomography (EIT) represents a promising advancement for personalized management of the acute respiratory distress syndrome (ARDS). However, accuracy is still hindered by the need for invasive monitoring to calibrate ventilation and perfusion. Here, we propose a non-invasive correction that uses only EIT data and characterized patients with more pronounced compensation of V'/Q mismatch.

METHODS:

We enrolled twenty-one ARDS patients on controlled mechanical ventilation. Cardiac output was measured invasively, and ventilation and perfusion were assessed by EIT. Relative V'/Q maps by EIT were calibrated to absolute values using the minute ventilation to invasive cardiac output (MV/CO) ratio (V'/Q-ABS), left unadjusted (V'/Q-REL), or corrected by MV/CO ratio derived from EIT data (V'/Q-CORR). The ratio between ventilation to dependent regions and perfusion reaching shunted units ( V D ' /QSHUNT) was calculated as an index of more effective hypoxic pulmonary vasoconstriction. The ratio between perfusion to non-dependent regions and ventilation to dead space units (QND/ V DS ' ) was calculated as an index of hypocapnic pneumoconstriction.

RESULTS:

Our calibration factor correlated with invasive MV/CO (r = 0.65, p < 0.001), showed good accuracy and no apparent bias. Compared to V'/Q-ABS, V'/Q-REL maps overestimated ventilation (p = 0.013) and perfusion (p = 0.002) to low V'/Q units and underestimated ventilation (p = 0.011) and perfusion (p = 0.008) to high V'/Q units. The heterogeneity of ventilation and perfusion reaching different V'/Q compartments was underestimated. V'/Q-CORR maps eliminated all these differences with V'/Q-ABS (p > 0.05). Higher V D ' / Q SHUNT correlated with higher PaO2/FiO2 (r = 0.49, p = 0.025) and lower shunt fraction (ρ = - 0.59, p = 0.005). Higher Q ND / V DS ' correlated with lower PEEP (ρ = - 0.62, p = 0.003) and plateau pressure (ρ = - 0.59, p = 0.005). Lower values of both indexes were associated with less ventilator-free days (p = 0.05 and p = 0.03, respectively).

CONCLUSIONS:

Regional V'/Q maps calibrated with a non-invasive EIT-only method closely approximate the ones obtained with invasive monitoring. Higher efficiency of shunt compensation improves oxygenation while compensation of dead space is less needed at lower airway pressure. Patients with more effective compensation mechanisms could have better outcomes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Síndrome do Desconforto Respiratório / Tomografia / Relação Ventilação-Perfusão / Impedância Elétrica Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Crit Care Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Síndrome do Desconforto Respiratório / Tomografia / Relação Ventilação-Perfusão / Impedância Elétrica Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Crit Care Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália