Your browser doesn't support javascript.
loading
Accuracy evaluation of a universal dental implant guide for simulating implantation in posterior area on dental molds.
Wang, Ruibin; Xu, Mingzhang; Wang, Lan; Zheng, Ziyang; Deng, Yunyi; Zeng, Maoyun; Yuan, Lingling; Peng, Peizhao; Liu, Qiqi; Yu, Ke.
Afiliação
  • Wang R; Dept. of Oral Implantology, The Affiliated Stomatological Hospital, Southwest Medical University, Luzhou 646000, China.
  • Xu M; Dept. of Oral Implantology, The Affiliated Stomatological Hospital, Southwest Medical University, Luzhou 646000, China.
  • Wang L; Dept. of Oral Implantology, The Affiliated Stomatological Hospital, Southwest Medical University, Luzhou 646000, China.
  • Zheng Z; Dept. of Oral Implantology, The Affiliated Stomatological Hospital, Southwest Medical University, Luzhou 646000, China.
  • Deng Y; Dept. of Oral Implantology, The Affiliated Stomatological Hospital, Southwest Medical University, Luzhou 646000, China.
  • Zeng M; Dept. of Oral Implantology, The Affiliated Stomatological Hospital, Southwest Medical University, Luzhou 646000, China.
  • Yuan L; Dept. of Oral Implantology, The Affiliated Stomatological Hospital, Southwest Medical University, Luzhou 646000, China.
  • Peng P; Dept. of Oral Implantology, The Affiliated Stomatological Hospital, Southwest Medical University, Luzhou 646000, China.
  • Liu Q; Dept. of Oral Implantology, The Affiliated Stomatological Hospital, Southwest Medical University, Luzhou 646000, China.
  • Yu K; Dept. of Oral Implantology, The Affiliated Stomatological Hospital, Southwest Medical University, Luzhou 646000, China.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(3): 365-371, 2024 Jun 01.
Article em En, Zh | MEDLINE | ID: mdl-39049658
ABSTRACT

OBJECTIVES:

This study aims to compare the accuracy of self-developed universal implant guide (SDG), 3D printed digital guide (DG), and free hand (FH) simulated implantation in the posterior tooth area of dental models.

METHODS:

Ten junior dentists were selected to place three implants in the 35, 37, and 46 tooth sites of the mandibular models (35, 36, 37, and 46 missing teeth) by using SDG, DG, and FH, and the process was repeated again to take the average value. Cone beam computed tomography (CBCT) was used to evaluate the global coronal deviation, global apical deviation, depth deviation, and angular deviation between the actual position and preoperative planned position.

RESULTS:

The coronal deviation and apical deviation of the three implant sites in the SDG group were not significantly different from those in the two other groups (P>0.05). The depth deviation and angular deviation in the SDG group were smaller than those in the DG group (P<0.05) and FH group (P<0.05), respectively. All deviations at site 37 in the SDG group were not different from those at site 35 (P>0.05), while the depth and angular deviation at site 37 in the DG group were higher than those at site 35 (P<0.05).

CONCLUSIONS:

The precision of the self-developed universal dental implant guide can meet the requirements of clinical posterior implantation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Modelos Dentários / Tomografia Computadorizada de Feixe Cônico / Mandíbula Limite: Humans Idioma: En / Zh Revista: Hua Xi Kou Qiang Yi Xue Za Zhi Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Modelos Dentários / Tomografia Computadorizada de Feixe Cônico / Mandíbula Limite: Humans Idioma: En / Zh Revista: Hua Xi Kou Qiang Yi Xue Za Zhi Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: China