Your browser doesn't support javascript.
loading
Electrode-based floating treatment wetlands: Insights into design operation factors influencing bioenergy generation and treatment performance.
Wojciechowska, Ewa; Strycharz, Joanna; Nawrot, Nicole; Ciesielski, Slawomir; Kowal, Przemyslaw; Czerwionka, Krzysztof; Matej-Lukowicz, Karolina.
Afiliação
  • Wojciechowska E; Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Gabriela Narutowicza 11/12 Street, 80-233 Gdansk, Poland. Electronic address: esien@pg.edu.pl.
  • Strycharz J; Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Gabriela Narutowicza 11/12 Street, 80-233 Gdansk, Poland.
  • Nawrot N; Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Gabriela Narutowicza 11/12 Street, 80-233 Gdansk, Poland.
  • Ciesielski S; Department of Environmental Biotechnology, University of Warmia and Mazury in Olsztyn, Olsztyn, Poland.
  • Kowal P; Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Gabriela Narutowicza 11/12 Street, 80-233 Gdansk, Poland.
  • Czerwionka K; Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Gabriela Narutowicza 11/12 Street, 80-233 Gdansk, Poland.
  • Matej-Lukowicz K; Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Gabriela Narutowicza 11/12 Street, 80-233 Gdansk, Poland.
Sci Total Environ ; 949: 175074, 2024 Nov 01.
Article em En | MEDLINE | ID: mdl-39079636
ABSTRACT
Exponential increases in energy consumption and wastewater have often irreversible environmental impacts. As a result, bio-electrochemical devices like microbial fuel cells (MFCs), which convert chemical energy in organic matter to electricity using exoelectrogenic bacteria, have gained interest. However, operational factors affecting efficiency and energy output need further study. This research investigated bioenergy production and COD, TN, and TP removal in mesoscale floating treatment wetlands (FTW-MFC) using Phragmites australis, Iris pseudacorus, and a mix of both. The Iris FTW-MFC achieved a high voltage peak of 2100 mV. The maximum power densities of 484 mW/m2, 1196 mW/m2, and 441 mW/m2 were observed for Phragmites, Iris, and mixed FTW-MFCs, respectively. Despite promising bioenergy yields, pollutant removal was unsatisfactory. A low area/height ratio (0.38 m2/0.8 m) and high loading rate (18.1 g/m2·d COD) boosted bioenergy output but hindered treatment performance and stressed plants, causing root decay. No significant pollutant removal differences were found between FTW-MFC and FTW. Higher relative plant growth rates occurred in the FTW-MFC. Microbial analysis shown that representatives of Pseudomonas and Clostridium species were consistently found across all samples, involved in both organic compound transformation and electricity generation, contributed to successful microscale results. A supporting microscale MFC experiment showed wastewater composition's impact on bioenergy yield and pollutant removal. Pre-inoculated reactors improved organic matter transformation and electricity generation, while aeration increased voltage and treatment performance. The role of plants requires further verification in future experiments.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fontes de Energia Bioelétrica / Eliminação de Resíduos Líquidos / Áreas Alagadas / Águas Residuárias Idioma: En Revista: Sci Total Environ Ano de publicação: 2024 Tipo de documento: Article País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fontes de Energia Bioelétrica / Eliminação de Resíduos Líquidos / Áreas Alagadas / Águas Residuárias Idioma: En Revista: Sci Total Environ Ano de publicação: 2024 Tipo de documento: Article País de publicação: Holanda