Your browser doesn't support javascript.
loading
Efficacy and safety of simultaneous combined Zephyr and Spiration valve therapy in patients with advanced pulmonary emphysema.
Dittrich, A Susanne; Kontogianni, Konstantina; Unterschemmann, Ann-Sophie; De Rossi, Susanne; Trudzinski, Franziska; Brock, Judith Maria; Gompelmann, Daniela; Heussel, Claus Peter; Herth, Felix J F; Eberhardt, Ralf.
Afiliação
  • Dittrich AS; Department of Pneumology and Critical Care Medicine, Thoraxklinik at the University Hospital Heidelberg, Heidelberg, Germany; Translational Lung Research Center Heidelberg (TLRC), German Center for Lung Research (DZL), Heidelberg, Germany. Electronic address: susanne.dittrich@med.uni-heidelberg.de.
  • Kontogianni K; Department of Pneumology and Critical Care Medicine, Thoraxklinik at the University Hospital Heidelberg, Heidelberg, Germany; Translational Lung Research Center Heidelberg (TLRC), German Center for Lung Research (DZL), Heidelberg, Germany.
  • Unterschemmann AS; Department of Pneumology and Critical Care Medicine, Thoraxklinik at the University Hospital Heidelberg, Heidelberg, Germany; Translational Lung Research Center Heidelberg (TLRC), German Center for Lung Research (DZL), Heidelberg, Germany.
  • De Rossi S; Department of Pneumology and Critical Care Medicine, Thoraxklinik at the University Hospital Heidelberg, Heidelberg, Germany; Translational Lung Research Center Heidelberg (TLRC), German Center for Lung Research (DZL), Heidelberg, Germany.
  • Trudzinski F; Department of Pneumology and Critical Care Medicine, Thoraxklinik at the University Hospital Heidelberg, Heidelberg, Germany; Translational Lung Research Center Heidelberg (TLRC), German Center for Lung Research (DZL), Heidelberg, Germany.
  • Brock JM; Department of Pneumology and Critical Care Medicine, Thoraxklinik at the University Hospital Heidelberg, Heidelberg, Germany; Translational Lung Research Center Heidelberg (TLRC), German Center for Lung Research (DZL), Heidelberg, Germany.
  • Gompelmann D; Department of Pneumology and Critical Care Medicine, Thoraxklinik at the University Hospital Heidelberg, Heidelberg, Germany; Department of Internal Medicine II, Division of Pulmonology, Medical University of Vienna, Vienna, Austria.
  • Heussel CP; Translational Lung Research Center Heidelberg (TLRC), German Center for Lung Research (DZL), Heidelberg, Germany; Department of Diagnostic and Interventional Radiology, Thoraxklinik at the University Hospital Heidelberg, Heidelberg, Germany.
  • Herth FJF; Department of Pneumology and Critical Care Medicine, Thoraxklinik at the University Hospital Heidelberg, Heidelberg, Germany; Translational Lung Research Center Heidelberg (TLRC), German Center for Lung Research (DZL), Heidelberg, Germany.
  • Eberhardt R; Department of Pneumology and Critical Care Medicine, Thoraxklinik at the University Hospital Heidelberg, Heidelberg, Germany; Pneumology & Critical Care Medicine, Asklepios Klinik Barmbek, Hamburg, Germany.
Respir Med ; 233: 107760, 2024 Nov.
Article em En | MEDLINE | ID: mdl-39098557
ABSTRACT

BACKGROUND:

Endoscopic lung volume reduction with valves is a minimally invasive treatment strategy for patients with severe pulmonary emphysema. Two valve systems are currently available Zephyr and Spiration valves. As these can be implanted simultaneously in the same procedure, the question arose as to the effect on lung function, exercise capacity and subjective disease perception after combined valve treatment.

METHODS:

We conducted a retrospective analysis of 108 patients with combined, simultaneous treatment of Zephyr and Spiration valves. The decision on which and how many valves to implant was based on the individual patient anatomy. Effects on lung function, exercise capacity and atelectasis formation as well as complications were evaluated 90- and 180-days post-treatment (90d-FU and 180d-FU).

RESULTS:

At 90d-FU (n = 90), the mean change was 86.7 ± 183.7 mL for FEV1 and -645.3 ± 1276.5 mL for RV, with responder rates of 39.8 % and 46.5 %, respectively. Complete atelectasis occurred in 16.7 % and partial atelectasis in 25.5 % of patients. Six-minute walking distance increased by 27.00 m [-1.50 - 68.50m]. The rates of pneumothorax (10.2 %) 6 months after treatment were not higher than in randomized controlled trials (RCTs). Likely due to the inclusion of high-risk patients, there was a higher incidence of severe COPD exacerbation (21.3 %) and pneumonia (12.0 %) compared to RCTs.

CONCLUSIONS:

The combined implantation of Zephyr and Spiration valves resulted in significant clinical and functional improvements with an acceptable risk profile. Therefore, the ability to combine both valve types in severe emphysema could be a promising option in endoscopic lung volume reduction.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pneumonectomia / Enfisema Pulmonar Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Respir Med Ano de publicação: 2024 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pneumonectomia / Enfisema Pulmonar Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Respir Med Ano de publicação: 2024 Tipo de documento: Article País de publicação: Reino Unido