Your browser doesn't support javascript.
loading
Accuracy of intraocular lens calculation formulas based on swept-source OCT biometer in cataract patients with phakic intraocular lens.
Zeng, Zongsheng; Zhu, Meiyi; Zhang, Guangbin.
Afiliação
  • Zeng Z; Xiamen Eye Center and Eye Institute of Xiamen University, Xiamen, China.
  • Zhu M; Xiamen Clinical Research Center for Eye Diseases, Xiamen, Fujian, China.
  • Zhang G; Xiamen Key Laboratory of Ophthalmology, Xiamen, Fujian, China.
BMC Ophthalmol ; 24(1): 326, 2024 Aug 05.
Article em En | MEDLINE | ID: mdl-39103785
ABSTRACT

PURPOSE:

To research the accuracy of intraocular lens (IOL) calculation formulas and investigate the effect of anterior chamber depth (ACD) and lens thickness (LT) measured by swept-source optical coherence tomography biometer (IOLMaster 700) in patients with posterior chamber phakic IOL (PC-pIOL).

METHODS:

Retrospective case series. The IOLMaster 700 biometer was used to measure axial length (AL) and anterior segment parameters. The traditional formulas (SRK/T, Holladay 1 and Haigis) with or without Wang-Koch (WK) AL adjustment, and new-generation formulas (Barret Universal II [BUII], Emmetropia Verifying Optical [EVO] v2.0, Kane, Pearl-DGS) were utilized in IOL power calculation.

RESULTS:

This study enrolled 24 eyes of 24 patients undergoing combined PC-pIOL removal and cataract surgery at Xiamen Eye Center of Xiamen University, Xiamen, Fujian, China. The median absolute prediction error in ascending order was EVO 2.0 (0.33), Kane (0.35), SRK/T-WKmodified (0.42), Holladay 1-WKmodified (0.44), Haigis-WKC1 (0.46), Pearl-DGS (0.47), BUII (0.58), Haigis (0.75), SRK/T (0.79), and Holladay 1 (1.32). The root-mean-square absolute error in ascending order was Haigis-WKC1 (0.591), Holladay 1-WKmodified (0.622), SRK/T-WKmodified (0.623), EVO (0.673), Kane (0.678), Pearl-DGS (0.753), BUII (0.863), Haigis (1.061), SRK/T (1.188), and Holladay 1 (1.513). A detailed analysis of ACD and LT measurement error revealed negligible impact on refractive outcomes in BUII and EVO 2.0 when these parameters were incorporated or omitted in the formula calculation.

CONCLUSION:

The Kane, EVO 2.0, and traditional formulas with WK AL adjustment displayed high prediction accuracy. Furthermore, the ACD and LT measurement error does not exert a significant influence on the accuracy of IOL power calculation formulas in highly myopic eyes implanted with PC-pIOL.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Refração Ocular / Catarata / Biometria / Tomografia de Coerência Óptica / Lentes Intraoculares Fácicas Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Refração Ocular / Catarata / Biometria / Tomografia de Coerência Óptica / Lentes Intraoculares Fácicas Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China