Your browser doesn't support javascript.
loading
Evaluation of Surface Roughness of Acrylic Denture Bases Polished Using Algishine, a Novel Polishing Material: An In Vitro Study.
Koppaka, Rahul; Shah, Khushali K; Ahmed, Nabeel; Echhpal, Urvi R.
Afiliação
  • Koppaka R; Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, IND.
  • Shah KK; Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, IND.
  • Ahmed N; Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, IND.
  • Echhpal UR; Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, IND.
Cureus ; 16(7): e63955, 2024 Jul.
Article em En | MEDLINE | ID: mdl-39104981
ABSTRACT
Introduction Surface roughness (Ra) significantly impacts the aesthetic and functional qualities of dental prosthetics. Traditional polishing involves pumice, a material routinely used in dental practice. This study introduces Algishine as a potential cost-effective eco-friendly alternative. Materials and methods A 3D design software (Geomagic) created a Standard Tesselation Language (STL) file of 10 mm x 10 mm x 2 mm. 30 STL file outputs were generated. The output was milled in wax. This was then flasked and processed. 30 acrylic resin specimens were fabricated and divided into two groups. Group A was polished using traditional pumice, and Group B was polished using Algishine. The Ra of each sample was measured using surface profilometry, with three readings per sample averaged for each group. Results Kruskal-Wallis test was performed to compare the two groups with the pre-testing samples, which showed p<0.05; indicating that there was a significant difference between the two groups. The average Ra value for unpolished acrylic was 7.105, while the specimens polished with pumice showed an Ra value of 2.218; specimens polished with novel material Algishine showed an Ra value of 1.743. This illustrates that Algishine achieves surface smoothness significantly superior to commonly used polishing agent and pumice. Discussion The results of our study demonstrate that Algishine, a novel polishing material derived from recycled alginate, effectively reduces the Ra of acrylic resin. This finding has significant implications, both clinically and environmentally. The primary clinical benefit of a smoother acrylic resin surface is the enhanced aesthetic appearance and increased patient comfort. A polished surface reduces plaque accumulation, thereby decreasing the risk of oral infections and improving the longevity of the dental prosthesis. The results show that Algishine achieves surface smoothness comparable to or better than pumice indicating that it can maintain, if not enhance, these clinical outcomes. Dental professionals can confidently use Algishine, knowing it meets the high standards required for patient care. Conclusion Algishine effectively reduces the Ra of acrylic resin, suggesting it is a viable, eco-friendly alternative to traditional pumice for dental polishing procedures. This indicates potential benefits in maintaining clinical outcomes while promoting environmental sustainability.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Cureus Ano de publicação: 2024 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Cureus Ano de publicação: 2024 Tipo de documento: Article País de publicação: Estados Unidos