Your browser doesn't support javascript.
loading
Cross-cultural adaptation and reliability of the European Portuguese version of the Musculoskeletal Health Questionnaire: A methodological study.
Ribeiro, Hermínia; Cruz, Eduardo Brazete; Castro, Ana; Rodrigues, Ana; Heleno, Bruno; Dias, Teresa L; Pires, Diogo.
Afiliação
  • Ribeiro H; Instituto Politécnico de Setúbal, Escola Superior de Saúde, Setúbal, Portugal.
  • Cruz EB; Instituto Politécnico de Setúbal, Escola Superior de Saúde, Setúbal, Portugal.
  • Castro A; Comprehensive Health Research Centre, NOVA Medical School, Universidade Nova de Lisboa, Lisboa, Portugal.
  • Rodrigues A; Instituto Politécnico de Setúbal, Escola Superior de Saúde, Setúbal, Portugal.
  • Heleno B; Centro de Linguística da Universidade NOVA de Lisboa (CLUNL), Lisboa, Portugal.
  • Dias TL; Comprehensive Health Research Centre, NOVA Medical School, Universidade Nova de Lisboa, Lisboa, Portugal.
  • Pires D; EpiDoC Unit, NOVA Medical School, NOVA University of Lisbon, Lisbon, Portugal.
PLoS One ; 19(8): e0308623, 2024.
Article em En | MEDLINE | ID: mdl-39116051
ABSTRACT

PURPOSE:

To culturally adapt the Musculoskeletal Health Questionnaire (MSK-HQ) to European Portuguese and evaluate its reliability in individuals with musculoskeletal conditions. MATERIALS AND

METHODS:

The study was carried out in two phases. In the first phase, the MSK-HQ was translated and culturally adapted. In the second phase, a longitudinal observational study was carried out with a convenience sample of participants with musculoskeletal conditions. Data collection began at the start of physiotherapy treatments by filling in the MSK-HQ and Numeric Pain Rating Scale (NPRS). After 4-7 days, the participants were asked to fill out the MSK-HQ once again, as well as the Patient Global Improvement Change (PGIC) scale. The data collected was used to study internal consistency, test-retest reliability, and measurement error. Floor and ceiling effects were also analysed.

RESULTS:

The MSK-HQ was successfully translated and adapted into European Portuguese. The second phase of the study had a sample of 191 participants. This study demonstrated high internal consistency (Cronbach's α = 0.885) and excellent test-retest reliability (ICC(2,1) = 0.908). The analysis of measurement error resulted in an SEM of 2.818 and an SDC at 7.811. No floor or ceiling effect was observed.

CONCLUSIONS:

The MSK-HQ-PT is a reliable instrument for measuring musculoskeletal health. Further studies on its validity and responsiveness are needed.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Comparação Transcultural / Doenças Musculoesqueléticas Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Portugal País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Comparação Transcultural / Doenças Musculoesqueléticas Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Portugal País de publicação: Estados Unidos