Reliability and validity of sprint performance using the Alex7 motorized device.
Skujyte, Austra; Lukonaitiene, Inga; Stanislovaitiene, Jurate; Silinskas, Viktoras; Bradauskiene, Kristina; Mamkus, Gediminas; Kamandulis, Sigitas.
Afiliação
  • Skujyte A; Institute of Sports Science and Innovation, Lithuanian Sports University, Kaunas, Lithuania.
  • Lukonaitiene I; Institute of Sports Science and Innovation, Lithuanian Sports University, Kaunas, Lithuania.
  • Stanislovaitiene J; Sports Coaching Department, Lithuanian Sports University, Kaunas, Lithuania.
  • Silinskas V; Sports Coaching Department, Lithuanian Sports University, Kaunas, Lithuania.
  • Bradauskiene K; Sports Coaching Department, Lithuanian Sports University, Kaunas, Lithuania.
  • Mamkus G; Sports Coaching Department, Lithuanian Sports University, Kaunas, Lithuania.
  • Kamandulis S; Institute of Sports Science and Innovation, Lithuanian Sports University, Kaunas, Lithuania.
Front Sports Act Living ; 6: 1412861, 2024.
Article em En | MEDLINE | ID: mdl-39119509
ABSTRACT

Introduction:

Advancements in technology have recently made it possible to implement effective training solutions across different environmental conditions. This study evaluated the reliability and validity of measures obtained from the innovative motorized device, Alex7 (Inosportas, Lithuania), and differences in speed and kinematic characteristics between resisted and assisted sprinting in young football players.

Methods:

Twenty-seven male athletes (mean age 16.5 ± 0.8 years; height 179.5 ± 6.9 cm; body weight 67.7 ± 8.3 kg) each performed 30-m sprints twice under three different conditions regular, resisted, and assisted sprinting. The Alex7 device provided the assistance and resistance during sprints. Results were compared with those from Witty timing gates. Ground contact time, flight time, stride length, and pace were measured using the OptoJump system. Reliability was assessed using two-way mixed intraclass correlation coefficients (ICCs) for single measures, the standard error of the mean (SEM), and the coefficient of variation (CV). Pearson's correlation coefficient determined the associations between Alex7 and Witty timing systems. Criterion-referenced validity was based on the mean difference and CV. Systematic bias was determined by limits of agreement using Bland-Altman analysis.

Results:

Running times obtained using the Alex7 equipment exhibited good to excellent test-retest reliability between sessions (ICC, 0.83-0.94) and good to excellent correlation (Pearson's r = 0.88-0.98) between the Alex7 and Witty systems in both assisted and resisted running conditions. However, the Alex7 device consistently produced longer running times than the Witty device (up to 0.16 s difference, p < 0.001). The different running conditions produced substantial variations in kinematic variables, such as stride length, ground contact time, and running speed (p < 0.001 for all), but the effects on flight time and running pace were smaller.

Discussion:

The Alex7 device shows high reliability for creating resisted and assisted running conditions for young football players. However, it tends to overestimate running time, necessitating caution when assessing the time parameters.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Front Sports Act Living Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Lituânia País de publicação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Front Sports Act Living Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Lituânia País de publicação: Suíça