Your browser doesn't support javascript.
loading
Colorimetric sensors constructed with one dimensional PtNi nanowire and Pt nanowire nanozymes for Hg2+ detection.
Guo, Jingyuan; Dong, Chenxin; Zhang, Xiang; Liu, Yujia; Leng, Yumin; Wang, Guo; Chen, Zhengbo.
Afiliação
  • Guo J; Department of Chemistry, Capital Normal University, Beijing, 100048, China.
  • Dong C; Department of Chemistry, Capital Normal University, Beijing, 100048, China.
  • Zhang X; Department of Chemistry, Capital Normal University, Beijing, 100048, China.
  • Liu Y; Department of Chemistry, Capital Normal University, Beijing, 100048, China.
  • Leng Y; School of Mathematics and Physics, Research Center for Environmental Monitoring and Sensor Design, Anqing Normal University, Anqing, 246133, China. Electronic address: yumin_leng@126.com.
  • Wang G; Department of Chemistry, Capital Normal University, Beijing, 100048, China. Electronic address: wangguo@cnu.edu.cn.
  • Chen Z; Department of Chemistry, Capital Normal University, Beijing, 100048, China. Electronic address: czb979216@sina.com.
Anal Chim Acta ; 1321: 343039, 2024 Sep 08.
Article em En | MEDLINE | ID: mdl-39155104
ABSTRACT

BACKGROUND:

In recent years, environmental pollution has attracted widespread global attention. Among them, environmental problems caused by heavy metal pollution pose a serious threat to human health and ecosystems. Mercury is a common heavy metal pollutant with high toxicity and wide distribution. Excessive intake of Hg2+ can cause permanent and severe damage to the nervous system, respiratory system, and kidneys in the human body. Therefore, developing both accurate and fast detection methods for Hg2+ is of great significance.

RESULTS:

A sensitive Hg2+ colorimetric sensor is designed based on PtNi nanowires (NWs) and Pt NWs with peroxidase-mimetic activity. PtNi NWs and Pt NWs catalyze the reaction of 3,3', 5,5'-tetramethylbenzidine (TMB) with hydrogen peroxide (H2O2) to produce blue oxidized TMB (oxTMB). The specific interaction of Pt-Hg significantly inhibits the peroxidase-mimetic activity of PtNi NW and Pt NW nanozymes, resulting in a lighter blue color. It is worth noting that compared with specific activity (SA) of Pt NWs (3.31 U/mg), PtNi NWs own superior SA (10.43 U/mg), which inevitably leads to a wider linear range of Hg2+ analysis (1 nM-200 µM) and a lower detection limit (0.6748 nM) for PtNi NWs-based colorimetric sensor, versus linear range (4 nM-5 µM) and LOD of 1.198 nM for Pt NWs-based colorimetric sensor, which are far below the Hg2+ threshold (10 nM) for drinking water set by the US Environmental Protection Agency.

SIGNIFICANCE:

The two nanozyme colorimetric sensors have been successfully used for the evaluation of Hg2+ in complex river water and tap water. Due to the advantages of simple operation, fast response, and high sensitivity, colorimetric sensors have broad application prospects in environmental monitoring.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Platina / Colorimetria / Nanofios / Mercúrio / Níquel Idioma: En Revista: Anal Chim Acta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: HOLANDA / HOLLAND / NETHERLANDS / NL / PAISES BAJOS / THE NETHERLANDS

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Platina / Colorimetria / Nanofios / Mercúrio / Níquel Idioma: En Revista: Anal Chim Acta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: HOLANDA / HOLLAND / NETHERLANDS / NL / PAISES BAJOS / THE NETHERLANDS