Your browser doesn't support javascript.
loading
Reduced order modelling of intracranial aneurysm flow using proper orthogonal decomposition and neural networks.
MacRaild, Michael; Sarrami-Foroushani, Ali; Lassila, Toni; Frangi, Alejandro F.
Afiliação
  • MacRaild M; Centre for Computational Imaging and Modelling in Medicine (CIMIM), University of Manchester, Manchester, UK.
  • Sarrami-Foroushani A; EPSRC Centre for Doctoral Training in Fluid Dynamics, University of Leeds, Leeds, UK.
  • Lassila T; Department of Computer Science, School of Engineering, University of Manchester, Manchester, UK.
  • Frangi AF; Centre for Computational Imaging and Modelling in Medicine (CIMIM), University of Manchester, Manchester, UK.
Int J Numer Method Biomed Eng ; 40(10): e3848, 2024 Oct.
Article em En | MEDLINE | ID: mdl-39155149
ABSTRACT
Reduced order modelling (ROMs) methods, such as proper orthogonal decomposition (POD), systematically reduce the dimensionality of high-fidelity computational models and potentially achieve large gains in execution speed. Machine learning (ML) using neural networks has been used to overcome limitations of traditional ROM techniques when applied to nonlinear problems, which has led to the recent development of reduced order models augmented by machine learning (ML-ROMs). However, the performance of ML-ROMs is yet to be widely evaluated in realistic applications and questions remain regarding the optimal design of ML-ROMs. In this study, we investigate the application of a non-intrusive parametric ML-ROM to a nonlinear, time-dependent fluid dynamics problem in a complex 3D geometry. We construct the ML-ROM using POD for dimensionality reduction and neural networks for interpolation of the ROM coefficients. We compare three different network designs in terms of approximation accuracy and performance. We test our ML-ROM on a flow problem in intracranial aneurysms, where flow variability effects are important when evaluating rupture risk and simulating treatment outcomes. The best-performing network design in our comparison used a two-stage POD reduction, a technique rarely used in previous studies. The best-performing ROM achieved mean test accuracies of 98.6% and 97.6% in the parent vessel and the aneurysm, respectively, while providing speed-up factors of the order 10 5 .
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Intracraniano / Redes Neurais de Computação Limite: Humans Idioma: En Revista: Int J Numer Method Biomed Eng Ano de publicação: 2024 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Intracraniano / Redes Neurais de Computação Limite: Humans Idioma: En Revista: Int J Numer Method Biomed Eng Ano de publicação: 2024 Tipo de documento: Article País de publicação: Reino Unido