The present report aims to describe the case of a duodenal obstruction ileus in a dairy cow that was caused by a cage magnet. The 4.7-year-old German Fleckvieh cow was hospitalized because of symptoms of intestinal obstruction such as anorexia, noticeable drop in milk yield, reduced defecation, dehydration and positive percussion and swinging auscultation in a circumscribed area cranial of the right flank over the last 2 ribs. Six months as well as 3 days prior to hospitalization the cow had already been treated for signs of hardware disease, which included administration of a cage magnet.After the initial clinical diagnostic procedure on hospital admission, a diagnostic laparotomy in the right paralumbar fossa was performed to identify the cause of the ileus. The cranial part of the duodenum was markedly dilated, and a solid foreign body was found obstructing the intestine immediately aboral to the duodenal sigmoid flexure. This was identified as a cage magnet, which was massaged in retrograde direction into the pyloric antrum and removed via abomasotomy. The cow recovered from surgical intervention and was discharged from the hospital 6 days later.The present report describes an unusual complication of cage magnet administration, which is a standard veterinary procedure and generally considered a safe treatment option in cows with clinical signs of acute traumatic reticuloperitonitis.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Doenças dos Bovinos
/
Íleus
/
Imãs
Limite:
Animals
Idioma:
En
Revista:
Tierarztl Prax Ausg G Grosstiere Nutztiere
Assunto da revista:
MEDICINA VETERINARIA
Ano de publicação:
2024
Tipo de documento:
Article
País de afiliação:
Alemanha
País de publicação:
Alemanha