Your browser doesn't support javascript.
loading
PneumaOCT: Pneumatic optical coherence tomography endoscopy for targeted distortion-free imaging in tortuous and narrow internal lumens.
Zhang, Tinghua; Yuan, Sishen; Xu, Chao; Liu, Peng; Chang, Hing-Chiu; Ng, Sze Hang Calvin; Ren, Hongliang; Yuan, Wu.
Afiliação
  • Zhang T; Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China.
  • Yuan S; Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China.
  • Xu C; Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China.
  • Liu P; Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China.
  • Chang HC; Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China.
  • Ng SHC; Department of Surgery, The Chinese University of Hong Kong, Hong Kong SAR, China.
  • Ren H; Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China.
  • Yuan W; Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China.
Sci Adv ; 10(35): eadp3145, 2024 Aug 30.
Article em En | MEDLINE | ID: mdl-39196931
ABSTRACT
The complex anatomy of internal luminal organs, like bronchioles, poses challenges for endoscopic optical coherence tomography (OCT). These challenges include limited steerability for targeted imaging and nonuniform rotation distortion (NURD) with proximal scanning. Using rotary micromotors for distal scanning could address NURD but raises concerns about electrical safety and costs. We present pneumaOCT, the first pneumatic OCT endoscope, comprising a steerable catheter with a soft pneumatic actuator and an imaging probe with a miniature pneumatic turbine. With a diameter of 2.8 mm, pneumaOCT allows for a bending angle of up to 237°, facilitating navigation through narrow turns. The pneumatic turbine enables adjustable imaging speeds from 51 to 446 revolutions per second. We demonstrate the pneumaOCT in vivo imaging of mouse esophagus and colon, as well as targeted and distortion-free imaging of peripheral bronchioles in a bronchial phantom and a porcine lung. This advancement substantially improves endoscopic OCT for navigational imaging in curved and narrow lumens.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia de Coerência Óptica Limite: Animals Idioma: En Revista: Sci Adv Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia de Coerência Óptica Limite: Animals Idioma: En Revista: Sci Adv Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Estados Unidos