Your browser doesn't support javascript.
loading
[Bioaccessibility characteristics of metals in welding fume and its application in exposure assessment].
Yu, M; Tang, Y; Ning, Y; Xu, Y; Tao, C Y; Zhang, X.
Afiliação
  • Yu M; Shanghai Municipal Center for Disease Control and Prevention Occupational Health Monitoring Department, Shanghai 200051, China.
  • Tang Y; Shanghai Municipal Center for Disease Control and Prevention Occupational Health Monitoring Department, Shanghai 200051, China.
  • Ning Y; Shanghai Municipal Center for Disease Control and Prevention Occupational Health Monitoring Department, Shanghai 200051, China.
  • Xu Y; Shanghai Municipal Center for Disease Control and Prevention Occupational Health Monitoring Department, Shanghai 200051, China.
  • Tao CY; Shanghai Municipal Center for Disease Control and Prevention Occupational Health Monitoring Department, Shanghai 200051, China.
  • Zhang X; Shanghai Municipal Center for Disease Control and Prevention Occupational Health Monitoring Department, Shanghai 200051, China.
Article em Zh | MEDLINE | ID: mdl-39223042
ABSTRACT

Objective:

To explore the bioaccessibility of the main metal components in welding fume welding fume in simulated lung fluid, and to evaluate the exposure level of each metal component in combination with the EPA inhalation exposure risk assessment model.

Methods:

In November 2022, the microscopic morphology characteristics of welding fumes were analyzed by scanning electron microscopy, the bioaccessibility of each metal component in lung fluid simulated normal and lung inflammatory states was analyzed by in vitro simulation method, and the exposure level of each metal component was calculated in combination with the EPA inhalation exposure risk assessment model.

Results:

The main metal components in carbon dioxide gas shielded welding fumes were Fe, Mn, Zn, Ti, Al, Cu, Cr, Cd, Ni and As, and the bioaccessibility in simulated normal lung interstitial fluid was 0.82%-1.84%, 5.07%-9.41%, 4.52%-7.23%, 5.10%-8.67%, 20.48%-29.60%, 5.27%-9.83%, 4.80%-7.56%, 0.07%-1.08%, 6.48%-13.84% and 33.02%-42.81%. The bioaccessibility of the above metal components in the lung fluid under simulated lung inflammation was 14.79%-27.45%, 34.53%-46.11%, 35.31%-59.13%, 16.45%-22.51%, 60.78%-76.51%, 26.58%-34.12%, 15.32%-25.87%, 2.0%-5.7%, 34.77%-43.33% and 71.34%-88.36%, respectively. Compared with the simulated lurg interstitial fluid, the bioaccessibility of metal components in the lung fluid under the simulated inflammatory state was increased, and the difference was statistically significant (P<0.05). The average daily exposure dose Mn in the two simulated lung fluids exceeded the inhalation reference limit (>50 times), and the average daily exposure dose Ti and Cr in the simulated lung inflammation exceeded the reference limit (>1.3 times) .

Conclusion:

Attention should be paid to the bioaccessibility characteristics of metal components in the exposure level and hazard assessment of welding fumes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Soldagem / Exposição Ocupacional / Exposição por Inalação / Poluentes Ocupacionais do Ar / Metais Limite: Humans Idioma: Zh Revista: Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi Assunto da revista: MEDICINA OCUPACIONAL Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Soldagem / Exposição Ocupacional / Exposição por Inalação / Poluentes Ocupacionais do Ar / Metais Limite: Humans Idioma: Zh Revista: Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi Assunto da revista: MEDICINA OCUPACIONAL Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: China