Comparison of efficacy and safety of different suction pressure for speeding non-ventilated lung collapse in uniport video-assisted thoracoscopic surgery: a randomized-controlled trial.
Li, Yulin; Huang, Haihui; Hang, Lihua.
Afiliação
  • Li Y; The First People's Hospital of Kunshan, Kunshan, 215300, China.
  • Huang H; The First People's Hospital of Kunshan, Kunshan, 215300, China.
  • Hang L; The First People's Hospital of Kunshan, Kunshan, 215300, China. zjhanglihua@foxmail.com.
BMC Surg ; 24(1): 247, 2024 Sep 03.
Article em En | MEDLINE | ID: mdl-39227846
ABSTRACT

BACKGROUND:

The bronchial suction has been applied in speeding lung collapse. Low suction pressure may not speed lung collapse, but high pressure causes occult lung injury. The aim of the study was to explore efficacy and safety of different suction pressure for speeding lung collapse.

METHODS:

Eighty-four subjects undergoing uniport video-assisted thoracoscopic surgery (VATS) were randomly assigned for non-suction (Group 0), -10 cmH2O suction pressure (Group - 10), and - 30 cmH2O suction pressure (Group - 30). The primary outcome were the lung collapse scores (LCS) at 0 min (T0) after the visualization of the lung using a 10-point visual analogue scale and area under the curve (AUC) of LCS over time. The secondary outcomes included disconnection from the ventilator, the assessment of occult lung injury using NOS-3 expression, histologic scores of lung injury, and lung W/D weight ratio, intraoperative hypoxemia, the incidence of perioperative pulmonary complications.

RESULTS:

Both the LCS at T0 and AUC analysis showed that compared with Group 0, Group - 10 and Group - 30 significantly achieved good lung collapse (P < 0.05), but no difference between Group - 10 and Group - 30. Four patients in Group 0 were treated with disconnection maneuver. The assessment of occult lung injury showed no differences.

CONCLUSIONS:

Applying - 10 cmH2O suction pressure for 1 min when pleural incision is a relatively safe method to promote lung collapse without the occurrence of occult lung injury. TRIAL REGISTRATION Chinese Clinical Trial Registry number, ChiCTR2200062991. Registered on 26/08/2022.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cirurgia Torácica Vídeoassistida Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Surg Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cirurgia Torácica Vídeoassistida Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Surg Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Reino Unido