Your browser doesn't support javascript.
loading
UPLC-MS/MS method for fluconazole determination in plasma and its application in Mexican patients with candidaemia.
Valero Rivera, Karla Paulina; Aquino, Martin Magaña; Azúa, Julia Sagahón; Carmen Romero Méndez, María Del; Medellín Garibay, Susanna Edith; Carmen Milán Segovia, Rosa Del; Gutiérrez, Fidel Martínez; Moreno, Silvia Romano.
Afiliação
  • Valero Rivera KP; Departamento de Farmacia, Facultad de Ciencias Químicas, Universidad Autónoma de San Luis Potosí, #6 Ave. Manuel Nava, San Luis Potosí, C.P.78210, México.
  • Aquino MM; Hospital Central "Dr. Ignacio Morones Prieto", #2395 Ave. Venustiano Carranza, San Luis Potosí, C.P.78290, México.
  • Azúa JS; Departamento de Farmacia, Facultad de Ciencias Químicas, Universidad Autónoma de San Luis Potosí, #6 Ave. Manuel Nava, San Luis Potosí, C.P.78210, México.
  • Carmen Romero Méndez MD; Departamento de Farmacia, Facultad de Ciencias Químicas, Universidad Autónoma de San Luis Potosí, #6 Ave. Manuel Nava, San Luis Potosí, C.P.78210, México.
  • Medellín Garibay SE; Departamento de Farmacia, Facultad de Ciencias Químicas, Universidad Autónoma de San Luis Potosí, #6 Ave. Manuel Nava, San Luis Potosí, C.P.78210, México.
  • Carmen Milán Segovia RD; Departamento de Farmacia, Facultad de Ciencias Químicas, Universidad Autónoma de San Luis Potosí, #6 Ave. Manuel Nava, San Luis Potosí, C.P.78210, México.
  • Gutiérrez FM; Departamento de Farmacia, Facultad de Ciencias Químicas, Universidad Autónoma de San Luis Potosí, #6 Ave. Manuel Nava, San Luis Potosí, C.P.78210, México.
  • Moreno SR; Departamento de Farmacia, Facultad de Ciencias Químicas, Universidad Autónoma de San Luis Potosí, #6 Ave. Manuel Nava, San Luis Potosí, C.P.78210, México.
Bioanalysis ; : 1-9, 2024 Sep 05.
Article em En | MEDLINE | ID: mdl-39234918
ABSTRACT

Aim:

An accurate and fast ultra-high performance liquid chromatography coupled with tandem mass spectrometry analytical method was developed and validated for quantifying fluconazole levels in human plasma according to the US FDA guidelines.Materials &

methods:

A simple protein precipitation by acetonitrile was employed for the sample preparation. The chromatographic separation was carried out using isocratic elution of water (0.1% formic acid) and acetonitrile on an Acquity ultra-high performance liquid chromatography HSS T3 column. Samples from ten adult patients diagnosed with candidemia who received fluconazole treatment were analyzed.Results &

conclusion:

The method demonstrated excellent linearity and stability within the 1-50 µg/ml range (r2 >0.999). The intraday and interday precision were determined with coefficient of variation values ranging from 1.4 to 4.38% and 2.8 to 6.6%, respectively. This rapid and selective method has successfully analyzed 27 plasma samples. The straightforward sample preparation in a single step and the reduced analysis time make this method suitable for adult patients with candidemia, leading to improved clinical outcomes.