Your browser doesn't support javascript.
loading
[Experiences with the infra-acetabular screw placement technique in acetabular fracture surgery].
Wu, Min; Guan, Jianzhong; Chen, Xiaotian; Wang, Xiaopan; Zhao, Peishuai; Li, Renjie; Chen, Jiaqiang; Liu, Leyu.
Afiliação
  • Wu M; Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical University, Anhui Key Laboratory of Tissue Transplantation, Bengbu Anhui, 233004, P. R. China.
  • Guan J; Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical University, Anhui Key Laboratory of Tissue Transplantation, Bengbu Anhui, 233004, P. R. China.
  • Chen X; Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical University, Anhui Key Laboratory of Tissue Transplantation, Bengbu Anhui, 233004, P. R. China.
  • Wang X; Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical University, Anhui Key Laboratory of Tissue Transplantation, Bengbu Anhui, 233004, P. R. China.
  • Zhao P; Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical University, Anhui Key Laboratory of Tissue Transplantation, Bengbu Anhui, 233004, P. R. China.
  • Li R; Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical University, Anhui Key Laboratory of Tissue Transplantation, Bengbu Anhui, 233004, P. R. China.
  • Chen J; Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical University, Anhui Key Laboratory of Tissue Transplantation, Bengbu Anhui, 233004, P. R. China.
  • Liu L; Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical University, Anhui Key Laboratory of Tissue Transplantation, Bengbu Anhui, 233004, P. R. China.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(9): 1040-1046, 2024 Sep 15.
Article em Zh | MEDLINE | ID: mdl-39300876
ABSTRACT

Objective:

To investigate the application experiences and effectiveness of the infra-acetabular screw (IAS) placement technique in acetabular fracture surgery.

Methods:

A clinical data of 34 patients with complex acetabular fractures with anterior and posterior columns separation, who were admitted between January 2019 and October 2023 and treated with IAS fixation, was retrospectively analyzed. There were 23 males and 11 females with an average age of 55.3 years (range, 18-78 years). The acetabular fractures caused by traffic accident in 20 cases, falling from height in 12 cases, crushing injury in 1 case, and bruising with a heavy object in 1 case. According to the Letournel-Judet classification, there were 7 cases of anterior column fracture, 8 cases of anterior wall/column plus posterior hemi-transverse fracture, 2 cases of T-shaped fracture, and 17 cases of both-column fracture. The time from injury to surgery was 4-21 days (mean, 8.6 days). The time of IAS placement and the intraoperative blood loss were recorded. After surgery, the X-ray film and CT scan were re-examined, and the modified Matta score was used to assess the quality of fracture reduction. The trajectory of IAS in the channel was analyzed based on CT scan, and the screw length was measured. During follow-up, the fracture healing was observed and the hip function was assessed according to the modified Merle d'Aubigné-Postel scoring system at last follow-up.

Results:

The IAS was successfully implanted in all 34 patients. The length of IAS ranged from 70 to 100 mm (mean, 86.2 mm). The time of IAS placement ranged from 10 to 40 minutes (mean, 20.7 minutes). The intraoperative blood loss ranged from 520 to 820 mL (mean, 716.8 mL). All patients were followed up 8-62 months (mean, 21.8 months). After surgery, 4 patients developed lateral femoral cutaneous nerve injury, 2 developed popliteal vein thrombosis of the lower extremity, 3 developed incision infection, and no surgical complication such as arteriovenous injury or obturator nerve palsy occurred. At last follow-up, the hip function was rated as excellent in 14 cases, good in 13 cases, fair in 4 cases, and poor in 3 cases according to the Merle d'Aubigné-Postel scoring system, with an excellent and good rate of 79.41%. Imaging re-examined showed that the quality of fracture reduction was rated as excellent in 9 cases, good in 19 cases, and poor in 6 cases according to the modified Matta score, with an excellent and good rate of 82.35%; and 25 (73.53%) IAS trajectories were located in the channel. All fractures obtained bony union, and the healing time was 12-24 weeks (mean, 18 weeks). During follow-up, there was no loosening or fracture of the plate and screws.

Conclusion:

IAS placement technique can effectively strengthen internal fixation and prevent fracture re-displacement, making it a useful adjunct for treating complex acetabular fractures with anterior and posterior columns separation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Parafusos Ósseos / Fraturas Ósseas / Fixação Interna de Fraturas / Acetábulo Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: Zh Revista: Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi Ano de publicação: 2024 Tipo de documento: Article País de publicação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Parafusos Ósseos / Fraturas Ósseas / Fixação Interna de Fraturas / Acetábulo Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: Zh Revista: Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi Ano de publicação: 2024 Tipo de documento: Article País de publicação: China