High incidence of low interstitial fluid glucose among type 2 diabetes patients with chronic kidney disease (CKD) despite adhering to appropriate glycated haemoglobin targets-has time come for robust integration of interstitial fluid glucose targets into glycaemic guidelines?
Tian, Kristy; Ang, Li Chang; Choudhary, Pratik; Choo, Jason Chon Jun; Bee, Yong Mong; Goh, Su-Yen; Teh, Ming Ming.
Afiliação
  • Tian K; Department of Endocrinology, Singapore General Hospital, Singapore.
  • Ang LC; Medicine Academic Clinical Programme, Singapore General Hospital, Singapore.
  • Choudhary P; Leicester Diabetes Center, University of Leicester, Leicester, United Kingdom.
  • Choo JCJ; Department of Renal Medicine, Singapore General Hospital, Singapore.
  • Bee YM; Department of Endocrinology, Singapore General Hospital, Singapore.
  • Goh SY; Department of Endocrinology, Singapore General Hospital, Singapore.
  • Teh MM; Department of Endocrinology, Singapore General Hospital, Singapore.
Diabet Med ; : e15438, 2024 Sep 20.
Article em En | MEDLINE | ID: mdl-39301988
ABSTRACT

AIM:

We aim to compare the burden of Level 1 (<4 mmol/L) and Level 2 (<3 mmol/L) hypoglycaemia between type 2 diabetes (T2D) patients with and without chronic kidney disease (CKD).

METHODS:

T2D subjects with and without CKD (eGFR<60 mL/min/1.73 m2) were recruited from a tertiary-care hospital. Subjects wore the Freestyle Libre-Pro sensor for 2 weeks. The number of hypoglycaemic events and intra-day difference in Level 1 and 2 hypoglycaemias were compared between the cohorts.

RESULTS:

We recruited 134

subjects:

74 with CKD (44 M30F) and 60 without CKD (36 M24F), with no difference in HbA1c between the two cohorts (66 ± 20 vs 64 ± 16 mmol/mol, p = 0.529). The CKD cohort had increased level 1 (OR 1.73, p = 0.011), level 2 hypoglycaemias (OR 2.16, p = 0.002), and glycaemic variability than the non-CKD cohort (35.3 ± 9.5 vs 32.3 ± 6.8%). The CKD cohort had more level 2 hypoglycaemia events nocturnally compared to day at 1.9 ± 3.1 vs. 1.4 ± 2.5 events/person within the two week sensor wearing period (p = 0.022), whereas there was no significant intra-day difference in the number of such events within the non-CKD cohort.

CONCLUSIONS:

The CKD cohort has a greater burden of hypoglycaemia despite being treated to similar HbA1c targets. The greater number of nocturnal events warrants safety concern. Interstitial fluid glucose targets should be incorporated into the glycaemic guidelines for T2D patients with CKD.