ABSTRACT
Carbon dioxide absorbents, such as soda lime and Baralyme brand absorbent, convert sevoflurane to CF2 = C(CF3)OCH2F, a vinyl ether called "Compound A," whose toxicity raises concerns regarding the safety of sevoflurane in rebreathing circuits. Because an increased inflow rate to an anesthetic circuit decreases rebreathing, we assumed that an increased rate would proportionately decrease the concentration of Compound A. In the present report, we measured the Compound A concentration resulting from the action of wet (standard) soda lime and wet (standard) Baralyme on 2% sevoflurane in a model anesthetic circuit, using inflow rates (0.5, 1.0, 2.0, 4.0, and 6.0 L/min), ventilations (5 and 10 L/min), and carbon dioxide production/removal (200 and 400 mL/min) found in clinical practice. An increase in inflow rate decreased Compound A concentration to lower levels as inflow rate approached minute ventilation. At lower inflow rates, increasing duration of sevoflurane inflow increased the concentration of Compound A, a finding consistent with a progressive increase in absorbent temperature from absorption of carbon dioxide and consequently greater sevoflurane degradation. There was no material difference between Baralyme and soda lime in the concentrations of Compound A produced at a particular inflow rate. An increase in ventilation increased the concentration of Compound A, having a much greater effect at high rather than low inflow rates. An increase in amount of carbon dioxide absorbed also increased the concentration of Compound A. We conclude that inflow rate, ventilation, and carbon dioxide production are major determinants of the concentration of Compound A.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Óxidos / Hidróxido de Sódio / Hidróxido de Cálcio / Compostos de Potássio / Compostos de Cálcio / Compostos de Bário / Éteres / Hidrocarbonetos Fluorados / Anestesia / Éteres Metílicos Tipo de estudo: Prognostic_studies Idioma: En Revista: Anesth Analg Ano de publicação: 1995 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Óxidos / Hidróxido de Sódio / Hidróxido de Cálcio / Compostos de Potássio / Compostos de Cálcio / Compostos de Bário / Éteres / Hidrocarbonetos Fluorados / Anestesia / Éteres Metílicos Tipo de estudo: Prognostic_studies Idioma: En Revista: Anesth Analg Ano de publicação: 1995 Tipo de documento: Article País de afiliação: Estados Unidos