Your browser doesn't support javascript.
loading
Suitability of artificial neural networks for feature extraction from cardiotocogram during labour.
Keith, R D; Westgate, J; Ifeachor, E C; Greene, K R.
Afiliação
  • Keith RD; Plymouth Perinatal Research Group, Plymouth Postgraduate Medical School, UK.
Med Biol Eng Comput ; 32(4 Suppl): S51-7, 1994 Jul.
Article em En | MEDLINE | ID: mdl-7967839
ABSTRACT
Fetal condition during labour is inferred from a continuous display of fetal heart rate and uterine contractions called the cardiotocogram (CTG). The CTG requires a considerable expertise for correct interpretation, which is not always available. We are developing an intelligent system to support clinical decision-making during labour. The system's performance depends on its ability to classify features from the CTG similarly to experts. Artificial neural networks (NNs) can be taught by experts for such tasks, and so may be particularly suitable. We found NNs suitable for feature extraction when the problem was reduced to small well defined tasks, and numerical algorithms were used to pre-process the raw data before application to the NNs. A NN with optimised dimensions was used in this way to classify the magnitude of decelerations, a feature clinicians find particularly difficult. The NN was compared with the algorithm used in a commercial antenatal monitor and six reviewers which included two CTG experts. The experts were consistent (89.7% and 97.0%) and agreed well with each other (81.0%), whereas the non-experts were less consistent and agreed less well. The NN agreed well with the experts (75.0% and 81.9%) but the algorithm agreed poorly (56.5% and 68.9%). It was found that the algorithm's performance could be improved (72.1% and 76.7%) when modified to use additional information. Our earlier attempts to fully classify the raw CTG using a single NN were unsuccessful because of the large number of data patterns. A simplified approach to classify the magnitude and timing of decelerations was also unsuitable when contraction data was of poor quality or absent.(ABSTRACT TRUNCATED AT 250 WORDS)
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Trabalho de Parto / Cardiotocografia / Redes Neurais de Computação Tipo de estudo: Prognostic_studies Limite: Female / Humans / Pregnancy Idioma: En Revista: Med Biol Eng Comput Ano de publicação: 1994 Tipo de documento: Article País de afiliação: Reino Unido
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Trabalho de Parto / Cardiotocografia / Redes Neurais de Computação Tipo de estudo: Prognostic_studies Limite: Female / Humans / Pregnancy Idioma: En Revista: Med Biol Eng Comput Ano de publicação: 1994 Tipo de documento: Article País de afiliação: Reino Unido
...