Your browser doesn't support javascript.
loading
Fully automated high-performance liquid chromatographic method for the determination of carzelesin (U-80,244) and metabolites (U-76,073 and U-76,074) in human plasma.
van Tellingen, O; Pels, E M; Henrar, R E; Schaaf, L J; Padbury, G E; Beijnen, J H; Nooijen, W J.
Afiliação
  • van Tellingen O; Department of Clinical Chemistry, Netherlands Cancer Institute, Amsterdam.
J Chromatogr ; 652(1): 51-8, 1994 Jan 14.
Article em En | MEDLINE | ID: mdl-8014227
ABSTRACT
Carzelesin (U80,244, I) is a cyclopropylpyrroloindole prodrug analog. The compound exerts its cytotoxic activity after conversion, via U-76,073 (II) to U-76,074 (III) by binding to the DNA minor groove in a sequence selective fashion. In pre-clinical investigations the drug displayed a broad spectrum activity against human xenografts in mice. To enable pharmacokinetic monitoring during the phase I clinical trials, we have developed a selective and sensitive assay for the parent compound and its two metabolites. Sample pre-treatment has been automated by using the ASPEC system and involves solid-phase extraction of the diluted plasma sample (13 in 20% v/v acetic acid) on an SPE-C18 precolumn followed by two consecutive washings with water and acetonitrile. The compounds are eluted with 600 microliters of dimethylacetamide and 500 microliters is injected on a Spherisorb-CN column. The sample is chromatographed using a linear gradient from 24% to 60% (v/v) acetonitrile in 20 mM phosphate buffer (pH 6.5). The eluate fraction containing the three compounds is heart-cutted in a 2-ml sample loop, switched onto a Spherisorb-ODS column and separation is accomplished using a mobile phase of acetonitrile-20 mM phosphate buffer pH 6.5 (6436, v/v). UV detection is used with absorbance monitored at 360 nm. This highly selective method offers a lower limit of detection of less than 1 ng/ml for each of the compounds using 1000 microliters of plasma and enables the quantification of the analytes with an acceptable precision and accuracy over a range of 1 to 50 ng/ml. The assay has been implemented in a phase I clinical trial.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Benzofuranos / Pró-Fármacos / Indóis / Antineoplásicos Limite: Humans Idioma: En Revista: J Chromatogr Ano de publicação: 1994 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Benzofuranos / Pró-Fármacos / Indóis / Antineoplásicos Limite: Humans Idioma: En Revista: J Chromatogr Ano de publicação: 1994 Tipo de documento: Article