Your browser doesn't support javascript.
loading
Technetium-99m labelled hydrazinonicotinamido human non-specific polyclonal immunoglobulin G for detection of infectious foci: a comparison with two other technetium-labelled immunoglobulin preparations.
Claessens, R A; Boerman, O C; Koenders, E B; Oyen, W J; van der Meer, J W; Corstens, F H.
Afiliação
  • Claessens RA; University Hospital Nijmegen, Department of Nuclear Medicine, P.O. Box 9101, 6500 HB Nijmegen, The Netherlands.
Eur J Nucl Med ; 23(4): 414-21, 1996 Apr.
Article em En | MEDLINE | ID: mdl-8612662
Recently a new linker - hydrazinonicotinate (HYNIC) - was introduced for labelling of proteins and peptides with technetium-99m. HYNIC and other linkers have been used for labelling of human non-specific polyclonal immunoglobulin G (hIgG) with 99mTc for the detection of infections. In this study we compared the tissue distribution of three different 99mTc-hIgG preparations in groups of five Wistar rats with a focal intramuscular infection with Staphylococcus aureus. We compared 99mTc-HYNIC-hIgG with 99mTc-hIgG labelled via the so-called Schwarz method (reduction of disulphide bonds) and with the 99mTc-labelled commercially available Technescan-HIG. Unlike the HYNIC linker, in the two other labelling methods free sulph-hydryl groups are involved in the binding of 99mTc. High-performance liquid chromatography analysis of the labelled preparations and of plasma samples revealed aggregate or polymer formation in all three agents; this was least pronounced in the product labelled by means of the Schwarz method. The tested preparations did not show signs of degradation in vitro. The difference in linker chemistry was reflected in the tissue distribution. Thus the biodistribution of 99mTc-HYNIC-hIgG was significantly different from the distribution of the two other preparations: abscess (1.4%+/-0.2%ID/g), muscle, liver, spleen, plasma, lung, bone marrow, and small intestine concentrations were higher at 24 h p.i.; kidney uptake (1.19%+/-0.08%ID/g) was significantly lower. The abscess-to-plasma and the abscess-to-muscle ratios (0.5 and 11, respectively), however, were in the same range for the three preparations tested. Quantitative analysis of the scintigraphs revealed that the total body clearance of 99mTc-HYNIC-hIgG was significantly slower than for the other agents. The abscess uptake of 99mTc-HYNIC-hIgG as a percentage of the remaining body activity was significantly higher. Based on its high abscess uptake, its low uptake in the kidneys and the high percentage of its abscess uptake in relation to the remaining body activity, we conclude that 99mTc-HYNIC-hIgG seems superior to the two other preparations tested for the detection of infections.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções Estafilocócicas / Imunoglobulina G / Compostos de Organotecnécio / Tecnécio / Abscesso / Doenças Musculares Tipo de estudo: Diagnostic_studies Limite: Animals / Humans / Male Idioma: En Revista: Eur J Nucl Med Ano de publicação: 1996 Tipo de documento: Article País de afiliação: Holanda País de publicação: Alemanha
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções Estafilocócicas / Imunoglobulina G / Compostos de Organotecnécio / Tecnécio / Abscesso / Doenças Musculares Tipo de estudo: Diagnostic_studies Limite: Animals / Humans / Male Idioma: En Revista: Eur J Nucl Med Ano de publicação: 1996 Tipo de documento: Article País de afiliação: Holanda País de publicação: Alemanha