Your browser doesn't support javascript.
loading
Surface contamination of titanium by abrading treatment.
Miyakawa, O; Watanabe, K; Okawa, S; Kanatani, M; Nakano, S; Kobayashi, M.
Afiliação
  • Miyakawa O; Department of Dental Materials and Technology, Niigata University School of Dentistry.
Dent Mater J ; 15(1): 11-21, 1996 Jun.
Article em En | MEDLINE | ID: mdl-8940534
ABSTRACT
This study investigated the contamination of abraded Ti surfaces. Using a polishing machine, specimens were abraded with waterproof SiC grit papers under water cooling. The abraded surfaces were examined using element analysis, X-ray diffraction, and hardness tests. Contaminant deposits with dimensions reaching about 30 microns were observed throughout the surface. In these deposits, Ti was apparently reduced by about 10% and replaced by Si and O. The chemical bond state of the Si was similar to that of SiC or a titanium silicide. The O was solute in Ti, which increased the surface hardness. The contaminant deposits were amorphous or very thin. The contamination of Ti, the extent of which was related to hardness, resulted from a reaction with abrasives.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Titânio / Polimento Dentário Idioma: En Revista: Dent Mater J Ano de publicação: 1996 Tipo de documento: Article