[A case report of total removal of infected pacemaker leads with cardiopulmonary bypass through right thoracotomy].
Kyobu Geka
; 50(11): 944-6, 1997 Oct.
Article
em Ja
| MEDLINE
| ID: mdl-9330516
ABSTRACT
A 61-year-old man with septicemia had four infected pacemaker leads, which were impossible to remove using simple traction method. He received CABG previously, and SVG anastomosed to LAD was patent. Redo median sternotomy had a possibility to make damage to SVG. Total removal of infected pacemaker was performed successfully with cardiopulmonary bypass through right thoracotomy.